Superior Fireplaces WCT6920WS Installation And Operation Instruction Manual

Superior Fireplaces WCT6920WS Installation And Operation Instruction Manual

Advertisement

Quick Links

SAVE THESE INSTRUCTIONS
FOR FUTURE REFERENCE
A French manual is available upon request. Order P/N 900995-02.
Ce manuel d'installation est disponible en francais, simplement en faire
la demande. Numéro de la pièce 900995-02.
Fireplace, also for use in mobile or
manufactured homes with solid fuel only.
• Hot! Do not touch! The glass and
surfaces of this appliance will be hot
during operation and will retain heat
for a while after shutting off the appli-
ance. Severe burns may result.
• Carefully supervise children in the
same room as appliance.
• If small children are present in the home, it is
recommended that this appliance be fitted with
an adjustable safety gate or barrier screen.
C
US
WARNING
Listed to standards:
ULC-S610 and UL-127
EPA Cert. No. 217-19
P900995-00
INSTALLATION AND
OPERATION INSTRUCTIONS
WCT6920WS
EPA Wood-Burning Fireplace
P/N 900995-00 REV. C 03/2021
MODEL
WCT6920WS
This installation manual will enable you to obtain a safe, efficient
and dependable installation of your fireplace system. Please read
and understand these instructions before beginning your installation.
Do not alter or modify the fireplace or its components under any cir-
cumstances. Any modification or alteration of the fireplace system,
including but not limited to the fireplace, chimney components and
accessories, may void the warranty, listings and approvals of this system
and could result in an unsafe and potentially dangerous installation.
IHP wood-burning fireplaces are designed for use as a supplemental
heater. They are not intended for continuous use as a primary heat
source.
WARNING
• The fireplace cannot be operated without a door.
Consult your dealer to select the correct replace-
ment door.
• The fireplace is equipped with a blower, electri-
cal connection must be made prior to fireplace
installation
• Important! To assure proper alignment of glass
doors: Install this fireplace in a square and plumb
condition, using shims as necessary at sides and/
or bottom.
• Install the fireplace only as described in these
instructions.
WARNING
This product can expose you to chemicals includ-
ing Carbon Black, which is known to the State of
California to cause cancer, and Carbon Monoxide,
which is known to the State of California to cause
birth defects or other reproductive harm. For more
information go to www.P65Warnings.ca.gov

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WCT6920WS and is the answer not in the manual?

Questions and answers

Summary of Contents for Superior Fireplaces WCT6920WS

  • Page 1 INSTALLATION AND OPERATION INSTRUCTIONS WCT6920WS EPA Wood-Burning Fireplace P/N 900995-00 REV. C 03/2021 MODEL WCT6920WS This installation manual will enable you to obtain a safe, efficient and dependable installation of your fireplace system. Please read and understand these instructions before beginning your installation.
  • Page 2: Table Of Contents

    • INTRODUCTION Finishing Guide Plate (included on Fire- Introduction ........Page 2 place) The WCT6920WS wood-burning fireplace is Parts Required .........Page 2 an energy efficient, heat circulating, closed OPTIONAL EQUIPMENT Optional Equipment ......Page 2 combustion fireplace. You will receive a lifetime Operating The Fireplace ....Page 2...
  • Page 3: Mobile Or Manufactured

    IMPORTANT! GENERAL SAFETY WARNING WARNING PRECAUTIONS. READ AND UNDERSTAND THESE SAFETY Use care when selecting window Always ensure that the air inlet to RULES BEFORE YOUR FIRST FIRE. treatments for windows located the fireplace is free from debris near the fireplace. Avoid using and any other obstructions that combustible flowing window can block the entrance of air.
  • Page 4: Starting And Maintaining A Fire

    entering the firebox. This allows for a more setting will depend on many factors, including WARNING precise control of the fire. The combustion air chimney length and the moisture content of control is located below the door on the left side. the wood.
  • Page 5: Important Cautions

    SMOKING – IMPORTANT CAUTIONS Carbon Monoxide Monitor Recommended CAUSES AND TROUBLESHOOTING A. Do not block the hot air vents to the fire- Carbon Monoxide Poisoning: Early signs of To reduce the likelihood of smoking when open- place as this will cause the fireplace to carbon monoxide poisoning are similar to the flu ing the door, set the combustion air controls to overheat.
  • Page 6: Maintaining Your Fireplace

    Chimney Maintenance Standard Regular chimney inspection and maintenance Cord of 8 Ft. Wood (2.4M) combined with proper operation will prevent chimney fires. Keep your chimney clean. Do not allow more than 1/16” (1.6 mm) creosote build up in your chimney. The amount of creosote will depend on variables such as frequency of 4 Ft.
  • Page 7: Finish Door Casing Care

    MAINTENANCE AND CARE (continued) Prohibited Fuels This heater is designed to burn natural wood only. Higher efficiencies and lower emissions generally result when burning air dried seasoned hardwoods, as compared to softwoods or to green or freshly cut hardwoods. DO NOT BURN: •...
  • Page 8: Refractory Installation

    MAINTENANCE AND CARE (continued) REFRACTORY REPLACEMENT The intense heat of the fire will normally cause hairline cracks in the refractory. These cracks can be minimized by proper curing as described in “First Fires”. They will not normally dimin- ish the effectiveness of the refractory. If large cracks develop, then the refractory should be replaced.
  • Page 9: Facade Installation

    FACADE INSTALLATION Install the Facade per instructions provided in WARNING: THE HEARTH EXTEN- Fireplace Facade Kit (ordered separately - see Page 26). SION IS TO BE INSTALLED ONLY After the Facade has been installed attach the AS ILLUSTRATED. adjustment handle by passing it through the lower The crack between the fireplace left slot of the facade, and screwing the threaded and the hearth extension must be...
  • Page 10: Glass Care

    Usually, no additional floor support is needed When selecting the location, the chimney outlet FIREPLACE INSTALLATION for the fireplace. The adequacy of the floor position and the direction of the wind are impor- Locating The Fireplace can be checked by first estimating the weight tant factor affecting the chimney performance.
  • Page 11: Framing Dimensions

    Corner Installation 39-5/8 (26) 2 x 3 Min. (1007) (1424) (header) (533) (2210) (1422) 79-1/4 (2013) Plywood 25-1/8* Back Wall of Chase / Enclosure 1/2” (638) Outside Chase Including Finishing Materials, if any (762) * Zero Clearance 37-1/4 * For flush framing installations from Back (946) Spacer to Wall...
  • Page 12 Insulate Joists Same As Ceiling INSULATED CHASE Storm Collar Roof Support CONSTRUCTION Flashing Attic Radiation Draft Stops Floor Shield Ceiling Wall Floor, Firestop Ceiling & NOTE: It is recommended Wall that the chase walls and floor CTDT be insulated in the same man - Termination •...
  • Page 13: Nailing Flanges

    Nailing Flanges Mantel and Facing Mantel and Facing Any mantel must be constructed of non- FLOOR: Four floor nailing flanges are provided (Side View) combustible material. to secure the fireplace to the floor (see Figure 13A). Bend the nailing flanges down so that Non- each flange is flush with the floor, then using Drywall...
  • Page 14: Fireplace Blower

    Drywall 2 x 3 Min. Open Door Remove Andirons Adjustable Standoffs Noncombustible Facing Rock Board or Other Figure 17A Figure 16C FIREPLACE BLOWER Rotate the blower forward to remove The fireplace comes equipped with a heat activated blower. It is located in the bottom of the fireplace, towards the front.
  • Page 15: Outside Air Kit

    Complete the Field Wiring Electrical connections and operation verification must be done prior to installing finishing materials on the fireplace face. Rheostat Verify proper operation after servicing. The gas valve is set in place and pre-wired at the factory. Snap Disc NOTE: Must be connected to the main power supply.
  • Page 16: Heatflo Convection Kit Installation

    HEATFLOW CONVECTION KIT INSTALLATION EPA Fireplace - HeatFlo Convection Kit Cat. No. Model Description The wood burning fireplace is approved for use with a Heatflow Convectin F3790 EPA-HEATFLO-KIT EPA Heatflo Conv. Kit Kit (hot air ducting system). Table 2 KIT CONTENTS (See Figure 20): The Ducted Flex Kit must use both hot air outlets and includes: 2 ea.
  • Page 17 It is recommended that the ducted flex kit duct system be installed in HEATFLOW CONVECTION KIT INSTALLATION (continued) the following order: INSTALLATION INSTRUCTIONS: 1. Plan and frame fireplace and outlet locations prior to ducted flex kit For approved installations, the ducted flex kit must meet the following installation.
  • Page 18 HEATFLOW CONVECTION KIT INSTALLATION (continued) 5. Fit the wall thimble onto the flex-pipe, prior to the wall thimble installation, and INSTALLATION NOTES: fasten together using 4 sheet metal screws. Measure from top of fireplace to • When framing for the outlet grill: The minimum height from planned outlet location and trim the flex-pipe if necessary.
  • Page 19: Chimney System

    Chimney Installation Notes 7. If the chimney extends higher than five (5) feet (1,500 mm) above its 1. The IHP fireplace model WCT6920WS may be installed only with point of contact with the roof, it must be secured using a roof brace.
  • Page 20: Only - Snap Pak Chimney

    UNITED STATES ONLY 5. The first chimney section through the joist area into attic is to be approximately two (2) feet. If the pipe sections in the attic are not enclosed, an insulation shield (SPIS) must be installed. CHIMNEY INSTALLATION Lower the insulation shield (SPIS) over the SP pipe until the SPIS flange is resting on the joist.
  • Page 21 INSTALLATION THROUGH A SIDE WALL 1. It is recomended that exterior mounted WALL FIRESTOP AIR CLEARANCE 2” TO (CAT. NO. SPWF) chimneys be enclosed below the roof line COMBUSTIBLES in geographical areas experiencing sus- CHIMNEY PIPE tained low ambient temperatures to help (CAT.
  • Page 22 ELBOW INSTALLATION FLASHING INSTALLATION 1. IHP provides a 15 (SPSE15) and 30 (SPSE30) Elbow to allow 1. Continue the SP chimney to the roof. Cut the roof opening, cen- ° ° chimneys to avoid framing members or roof peaks. A maximum tered over the chimney.
  • Page 23 TERMINATION Additional support is required above the roof if the chimney height exceeds four (4) feet. Many building codes specify a minimum chimney heights above the Select the proper support for your application-using either a roof roof top. These specifications are summarized in what is known as the brace (Figure 36), or a support band with guy wires (Figure 37) “Ten Foot Rule”.
  • Page 24: Chimney Chase And Multiple Terminations

    CANADA ONLY CHIMNEY CHASE AND MULTIPLE TERMINATIONS CHIMNEY INSTALLATION For the purpose of this manual, a chimney chase is considered a part of the chimney system rather than part of a building. The termination must INSTRUCTIONS be placed a minimum of 18” (460 mm) above the chase. For installations where more than one chimney is located in the same CANADA APPROVED VENTING SYSTEMS: chase or within the same area, we suggest that their terminations be...
  • Page 25: Masonry Application Instructions

    Follow these steps: INSTALLATION INSTRUCTIONS FOR MASONRY APPLICATIONS FOR BOTH UNITED STATES AND CANADA 1. Position the fireplace in its location. Temporarily install the 30° insu- WARNING: Before starting the installation, the masonry chimney must lated elbow on the top of the fireplace and, using a level, mark with an be inspected by a qualified chimney sweep.
  • Page 26: Installation Accessories

    OPTIONAL INSTALLATION ACCESSORIES Installation Accessories Fireplace Kits Description Cat./ Part No. Description Cat./ Part No. Central Forced Air Kit Accessories Facades (Required - Order Separately) Central Forced Air Kit, Central forced air kit including: blower Facade Black, BTCEFBK BTCEFBK (BISZY), flex adaptor (BISAF), 2 clamps, variable speed control (VRUW), thermo-disk (VTU), fan to flexible pipe BISFWK-1 Doors (Required - Order Separately)
  • Page 27: Replacement Parts

    Backdraft damper, BISBD BISBD Insulation Shield 6SPIS F3975 Fireplace to Flex adaptor and 2 clamps, BISAF BISAF Flat Flashing 6SPFF F3976 WCT6920WS Metal Fab Collar and Sleeve F4189 2/12-5/12 Flashing 6SPF5 F3977 Top Standoff Header Shield Assy F4713 6/12-10/12 Flashing 6SPF10 F3978...
  • Page 28: Chimney Components Lists

    CANADA: Security Chimney: Secure Temp ASHT+ or S2100+, DuraVent: DuraTech Canada or Duratech Premium Contact your Security Chimneys or DuraVent Distributor or Dealer for ordering information. Security Chimneys ® M&G DuraVent 1-800-835-4429 450-973-9999 2125 Monterey, Laval, Quebec 877 Cotting Court, Vacaville, 1-800-361-4909 (USA) Canada, H7L 3T6 California, 95688...
  • Page 29: Safety/Listing Label

    SAFETY / LISTING LABEL WCT6920WS...
  • Page 30 NOTES ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 31: Warranty

    Innovative Hearth Products Superior Brand Wood-Burning Fireplace ® 20 Year Limited Warranty THE WARRANTY Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior ® Brand wood burning fireplace ("Product") to be free from defects in materials and workmanship at the time of manufacture. The Product body, firebox and ceramic glass carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited Warranty against thermal breakage only.
  • Page 32: Product Reference Information

    WARRANTY Normally, all parts should be ordered through your IHP distributor or dealer. Parts will be shipped at prevailing prices at time of order. Your fireplace is covered by a limited warranty. Please read the warranty When ordering repair parts, always give the following information: to be familiar with its coverage.