Superior Fireplaces WCT4920WS Installation And Operation Instruction Manual

Superior Fireplaces WCT4920WS Installation And Operation Instruction Manual

Advertisement

Quick Links

SAVE THESE INSTRUCTIONS
FOR FUTURE REFERENCE
A French manual is available upon request. Order P/N 901173-02.
Ce manuel d'installation est disponible en francais, simplement en faire
la demande. Numéro de la pièce 901173-02.
Fireplace, also for use in mobile or
manufactured homes with solid fuel only.
• Hot! Do not touch! The glass and
surfaces of this appliance will be hot
during operation and will retain heat
for a while after shutting off the appli-
ance. Severe burns may result.
• Carefully supervise children in the
same room as appliance.
• If small children are present in the home, it is
recommended that this appliance be fitted with
an adjustable safety gate or barrier screen.
C
US
WARNING
Listed to standards:
ULC-S610 and UL-127
EPA Cert. No. 217-19
INSTALLATION AND
OPERATION INSTRUCTIONS
WCT4920WS
EPA Wood-Burning Fireplace
P/N 901173-00 REV. NC 08/2021
MODEL
WCT4920WS
This installation manual will enable you to obtain a safe, efficient
and dependable installation of your fireplace system. Please read
and understand these instructions before beginning your installation.
Do not alter or modify the fireplace or its components under any cir-
cumstances. Any modification or alteration of the fireplace system,
including but not limited to the fireplace, chimney components and
accessories, may void the warranty, listings and approvals of this system
and could result in an unsafe and potentially dangerous installation.
IHP wood-burning fireplaces are designed for use as a supplemental
heater. They are not intended for continuous use as a primary heat
source.
• The fireplace cannot be operated without a door.
Consult your dealer to select the correct replace-
ment door.
• The fireplace is equipped with a blower, electri-
cal connection must be made prior to fireplace
installation
• Important! To assure proper alignment of glass
doors: Install this fireplace in a square and plumb
condition, using shims as necessary at sides and/
or bottom.
• Install the fireplace only as described in these
instructions.
This product can expose you to chemicals includ-
ing Carbon Black, which is known to the State of
California to cause cancer, and Carbon Monoxide,
which is known to the State of California to cause
birth defects or other reproductive harm. For more
information go to www.P65Warnings.ca.gov
P901173-00
WARNING
WARNING

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WCT4920WS and is the answer not in the manual?

Questions and answers

Summary of Contents for Superior Fireplaces WCT4920WS

  • Page 1 INSTALLATION AND OPERATION INSTRUCTIONS WCT4920WS EPA Wood-Burning Fireplace P/N 901173-00 REV. NC 08/2021 MODEL WCT4920WS This installation manual will enable you to obtain a safe, efficient and dependable installation of your fireplace system. Please read and understand these instructions before beginning your installation.
  • Page 2: Table Of Contents

    • Outside Air Kit (Included w/Fireplace) INTRODUCTION Introduction ........Page 2 OPTIONAL EQUIPMENT The WCT4920WS wood-burning fireplace is Parts Required .........Page 2 an energy efficient, heat circulating, closed • Additional Equipment (optional) Optional Equipment ......Page 2 combustion fireplace. You will receive a lifetime - Forced Air Kit Operating The Fireplace ....Page 2...
  • Page 3: Mobile Or Manufactured

    IMPORTANT! GENERAL SAFETY WARNING WARNING PRECAUTIONS. READ AND UNDERSTAND THESE SAFETY Use care when selecting window Always ensure that the air inlet to RULES BEFORE YOUR FIRST FIRE. treatments for windows located the fireplace is free from debris near the fireplace. Avoid using and any other obstructions that combustible flowing window can block the entrance of air.
  • Page 4: Starting And Maintaining A Fire

    entering the firebox. This allows for a more setting will depend on many factors, including WARNING precise control of the fire. The combustion air chimney length and the moisture content of control is located below the door on the left side. the wood.
  • Page 5: Important Cautions

    SMOKING – IMPORTANT CAUTIONS Carbon Monoxide Monitor Recommended CAUSES AND TROUBLESHOOTING A. Do not block the hot air vents to the fire- Carbon Monoxide Poisoning: Early signs of To reduce the likelihood of smoking when open- place as this will cause the fireplace to carbon monoxide poisoning are similar to the flu ing the door, set the combustion air controls to overheat.
  • Page 6: Maintaining Your Fireplace

    MAINTENANCE AND CARE Standard Cord of Chimney Maintenance 8 Ft. Wood (2.4M) Regular chimney inspection and maintenance combined with proper operation will prevent chimney fires. Keep your chimney clean. Do not allow more than 1/16” (1.6 mm) creosote build 4 Ft. (1.2M) up in your chimney.
  • Page 7: Finish Door Casing Care

    MAINTENANCE AND CARE (continued) Prohibited Fuels This heater is designed to burn natural wood only. Higher efficiencies and lower emissions generally result when burning air dried seasoned hardwoods, as compared to softwoods or to green or freshly cut hardwoods. DO NOT BURN: •...
  • Page 8: Refractory Installation

    MAINTENANCE AND CARE (continued) REFRACTORY REPLACEMENT The intense heat of the fire will normally cause hairline cracks in the refractory. These cracks can be minimized by proper curing as described in “First Fires”. They will not normally dimin- ish the effectiveness of the refractory. If large cracks develop, then the refractory should be replaced.
  • Page 9: Facade Installation

    FACADE INSTALLATION Install the Facade per instructions provided in WARNING: THE HEARTH EXTEN- Fireplace Facade Kit (ordered separately - see Page 27). SION IS TO BE INSTALLED ONLY After the Facade has been installed attach the AS ILLUSTRATED. adjustment handle by passing it through the lower The crack between the fireplace left slot of the facade, and screwing the threaded and the hearth extension must be...
  • Page 10: Glass Care

    FIREPLACE INSTALLATION Usually, no additional floor support is needed When selecting the location, the chimney outlet for the fireplace. The adequacy of the floor position and the direction of the wind are impor- Locating The Fireplace can be checked by first estimating the weight tant factor affecting the chimney performance.
  • Page 11: Framing Dimensions

    Corner Installation 39-5/8 (26) 2 x 3 Min. (1007) (1424) (header) (533) (2210) (1422) 79-1/4 (2013) Plywood 25-1/8* Back Wall of Chase / Enclosure 1/2” Outside Chase (638) Including Finishing Materials, if any (762) * Zero Clearance 37-1/4 from Back * For flush framing installations (946) Spacer to Wall...
  • Page 12 Insulate Joists Same As Ceiling Storm Collar INSULATED CHASE Roof Support CONSTRUCTION Flashing Attic Radiation Draft Stops Floor Shield Ceiling Wall Floor, Firestop Ceiling & NOTE: It is recommended Wall that the chase walls and floor CTDT be insulated in the same man - Termination •...
  • Page 13 NOTE: The facade depth can be adjusted to cover facing materi- als ranging from1/2” to 1” thick. For facing materials exceeding 1”, room must be left for the façade to install within the facing material around its perimeter. See below for detailed installation options 1.
  • Page 14: Nailing Flanges

    Nailing Flanges Mantel and Facing Any mantel must be constructed of non-combustible material. FLOOR: Four floor nailing flanges are provided to secure the fireplace to the floor (see Figure 13). Bend the nailing flanges down so that each flange is flush with the floor, then using nails Mantel and Facing or screws, secure the fireplace to the floor (2 (Side View)
  • Page 15: Fireplace Blower

    FIREPLACE BLOWER The fireplace comes equipped with a heat activated blower. It is located in the bottom of the fireplace, towards the front. It uses 120V and must be connected to the main electrical circuit by a qualified electrician. For connection, use the electrical box supplied with the unit located on the bottom right corner of the fireplace.
  • Page 16: Outside Air Kit

    Complete the Field Wiring Electrical connections and operation verification must be done prior to installing finishing materials on the fireplace face. Rheostat Verify proper operation after servicing. NOTE: Must be connected to the main power supply. Snap Disc NOTE: The junction box is located on the left side of the fireplace (Figure 37).
  • Page 17: Heatflo Convection Kit Installation

    HEATFLOW CONVECTION KIT INSTALLATION EPA Fireplace - HeatFlo Convection Kit Cat. No. Model Description This wood burning fireplace is approved for use with a HeatFlo Convection Kit (hot air ducting system). F3790 EPA-HEATFLO-KIT EPA Heatflo Conv. Kit NOTE: If the Clean Face facade is to be used, a HeatFlo Kit designed Table 2 specifically for this fireplace MUST be installed.
  • Page 18 It is recommended that the ducted flex kit duct system be installed in HEATFLOW CONVECTION KIT INSTALLATION (continued) the following order: INSTALLATION INSTRUCTIONS: 1. Plan and frame fireplace and outlet locations prior to ducted flex kit For approved installations, the ducted flex kit must meet the following installation.
  • Page 19 HEATFLOW CONVECTION KIT INSTALLATION (continued) 5. Fit the wall thimble onto the flex-pipe, prior to the wall thimble installation, and INSTALLATION NOTES: fasten together using 4 sheet metal screws. Measure from top of fireplace to • When framing for the outlet grill: The minimum height from planned outlet location and trim the flex-pipe if necessary.
  • Page 20: Chimney System

    THE CHIMNEY SYSTEM (UNITED STATES & CANADA) 6. The chimney must extend at least three (3) feet (915 mm) above its point of contact with the roof and at least two (2) feet (610 mm) higher than any wall, roof or building within ten (10) feet (3m) of it. Chimney Installation Notes 7.
  • Page 21: Only - Snap Pak Chimney

    UNITED STATES ONLY 5. The first chimney section through the joist area into attic is to be approximately two (2) feet. If the pipe sections in the attic are not enclosed, an insulation shield (SPIS) must be installed. CHIMNEY INSTALLATION Lower the insulation shield (SPIS) over the SP pipe until the SPIS flange is resting on the joist.
  • Page 22 INSTALLATION THROUGH A SIDE WALL 1. It is recomended that exterior mounted WALL FIRESTOP AIR CLEARANCE 2” TO (CAT. NO. SPWF) chimneys be enclosed below the roof line COMBUSTIBLES in geographical areas experiencing sus- CHIMNEY PIPE tained low ambient temperatures to help (CAT.
  • Page 23 ELBOW INSTALLATION FLASHING INSTALLATION 1. IHP provides a 15 (SPSE15) and 30 (SPSE30) Elbow to allow 1. Continue the SP chimney to the roof. Cut the roof opening, cen- ° ° chimneys to avoid framing members or roof peaks. A maximum tered over the chimney.
  • Page 24 TERMINATION Additional support is required above the roof if the chimney height exceeds four (4) feet. Many building codes specify a minimum chimney heights above the Select the proper support for your application-using either a roof roof top. These specifications are summarized in what is known as the brace (Figure 36), or a support band with guy wires (Figure 37) “Ten Foot Rule”.
  • Page 25: Chimney Chase And Multiple Terminations

    CANADA ONLY CHIMNEY CHASE AND MULTIPLE TERMINATIONS CHIMNEY INSTALLATION For the purpose of this manual, a chimney chase is considered a part of the chimney system rather than part of a building. The termination must INSTRUCTIONS be placed a minimum of 18” (460 mm) above the chase. For installations where more than one chimney is located in the same CANADA APPROVED VENTING SYSTEMS: chase or within the same area, we suggest that their terminations be...
  • Page 26: Masonry Application Instructions

    Follow these steps: INSTALLATION INSTRUCTIONS FOR MASONRY APPLICATIONS FOR BOTH UNITED STATES AND CANADA 1. Position the fireplace in its location. Temporarily install the 30° insu- WARNING: Before starting the installation, the masonry chimney must lated elbow on the top of the fireplace and, using a level, mark with an be inspected by a qualified chimney sweep.
  • Page 27: Installation Accessories

    OPTIONAL INSTALLATION ACCESSORIES Fireplace Kits Installation Accessories Description Cat./ Part No. Description Cat./ Part No. Central Forced Air Kit Accessories Facade Options (Required - Order Separately) Central Forced Air Kit, Central forced air kit including: blower F4781 Facade, Louvered, Arch Open, Black (BISZY), flex adaptor (BISAF), 2 clamps, variable speed control (VRUW), thermo-disk (VTU), fan to flexible pipe BISFWK-1...
  • Page 28: Replacement Parts

    REPLACEMENT PARTS LIST SPECIFICATIONS WCT4920WS Replacement Parts Cat. No. Model No. F4779 WCT4920WS Description Cat. No. Blower Assembly, Single F3866 Blower Wiring Harness F4801 EPA Estimated Model Emission Rate Heat Output Efficiency Blower motor speed control (wall mount), VRUW VRUW WCT4920WS 1.9 g/hr...
  • Page 29: Chimney Components Lists

    CANADA: Security Chimney: Secure Temp ASHT+ or S2100+, DuraVent: DuraTech Canada or Duratech Premium Contact your Security Chimneys or DuraVent Distributor or Dealer for ordering information. Security Chimneys ® M&G DuraVent 1-800-835-4429 450-973-9999 2125 Monterey, Laval, Quebec 877 Cotting Court, Vacaville, 1-800-361-4909 (USA) Canada, H7L 3T6 California, 95688...
  • Page 30: Safety/Listing Label

    SAFETY / LISTING LABEL WCT4920WS...
  • Page 31: Warranty

    Innovative Hearth Products Superior Brand Wood-Burning Fireplace ® 20 Year Limited Warranty THE WARRANTY Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior Brand wood burning fireplace ("Product") to be free from defects in materials and ® workmanship at the time of manufacture. The Product body, firebox and ceramic glass carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited Warranty against thermal breakage only.
  • Page 32: Product Reference Information

    WARRANTY Normally, all parts should be ordered through your IHP distributor or dealer. Parts will be shipped at prevailing prices at time of order. Your fireplace is covered by a limited warranty. Please read the warranty When ordering repair parts, always give the following information: to be familiar with its coverage.

Table of Contents