  • Page 1 PORTADAVIT QUANTUM Assembly & Operation Guide REIDLIFTING.COM...
  • Page 2 Contents PORTADAVIT QUANTUM Correct Operation ATEX Intended Use ATEX Inspection Prior to Initial Operation Classification [Zone 2] Inspection Before Starting Work Classification [Zone 1] Lightweight. Maximum Capacity Spark Formation Temperature Range Static Electricity Notes for Correct Operation Inspection, Maintenance & Repair Disclaimer Assembly Instructions Portable.
  • Page 3: Correct Operation

    Do not use this product if it does not rotate hoist in case the dynamic effects of this reduce hoist, chain or load the overall capacity of the davit. REID Lifting’s freely in the bearing or if the bottom flange Grey...
  • Page 4 Fall Protection Additional Notes for Correct Operation Warning IRATA REID lifting sockets & extensions have been The equipment should not be used outside When being used as part of a fall protection Ensure suitable and appropriately rated When using the Davit in conjunction with any...
  • Page 5: Inspection And Maintenance

    Inspection & Maintenance PORTADAVIT QUANTUM Regular Inspections Maintenance & Repair Storage & Transportation Overload Indicator The following information is based on REID Before use, the product should be inspected for Lifting’s recommendations and does not remove visual defects using the checklist below: To ensure that the product’s remains in safe In order to ensure correct operation, the conditions When transporting the components, take note of...
  • Page 6 Depending upon the socket type, there are a worst-case loading directions, sustained for a 150% of the goods capacity at the device’s by REID Lifting are approved to be used with this The Cast & Resin Bonded sockets can be number of different installation options. If bolts duration of 3 minutes.
  • Page 7 Inspections must be instigated by the user prior and REID Lifting Ltd will not accept any vapours or mists or by air and dusts mixtures are of protection where mixtures of air and gases, applies especially in the case of rust or surface materials that could create electrostatic charging.
  • Page 8 Assembly Instructions PORTADAVIT QUANTUM The PORTA DAVIT QUANTUM (Type S) and its constituent components are described in the image below. The use of a socket extension is optional and the socket type may vary between a Top Mount, Side Mount, Bridge Mount, Cast In or Resin Bonded, depending on application. Assembling the PORTA DAVIT QUANTUM - Type S (Shackle only) Head PORTA DAVIT QUANTUM...
  • Page 9 Assembly Instructions PORTADAVIT QUANTUM The PORTA DAVIT QUANTUM (Type W) and its constituent components are described in the image below. The use of a socket extension is optional and the socket type may vary between a Top Mount, Side Mount, Bridge Mount, Cast In or Resin Bonded, depending on application. Assembling the PORTA DAVIT QUANTUM - Type W (Winched) Head 3x Sheaves...
  • Page 10 Assembly Instructions PORTADAVIT QUANTUM Variants & Adjusting the Radius Options. The decal specifies the radius values with the upper value stating the outer shackle position and the lower value stating the inner shackle position The operating dimensions can be found on page 19 Ensure the radius adjustment pin is fully engaged before use.
  • Page 11: Variants & Options

    Variants & Options Notes PORTADAVIT QUANTUM The list below outlines additional options When the rotational handle is attached to the Fig 1 available which can be fitted to the PORTADAVIT Davit the following points must be observed: QUANTUM; Attach the rotational handle to the column of the Davit at a suitable height [Ideal position Rotational Handle should be around hip height].
  • Page 12 Dimensions PORTADAVIT QUANTUM (Winched) PORTADAVIT PORTADAVIT (Shackled) QUANTUM QUANTUM 296mm Radius Dimensions (mm) Overall height Adjustment Height to outer shackle Points Part Number Height to inner shackle 2007 1935 1799 1200 1100 Radius to outer shackle PDQ1S Radius to inner shackle 1680mm 600KG 2061...
  • Page 13: Quality & Safety

    Accreditations Conformité Européenne [CE] & Testing Product IPR LEEA Membership - REID Lifting is a full member of the Lifting Equipment Engineers Association UK Conformity Assessed [UKCA] This product complies with the following: Quality and Safety are at the heart of the REID...
  • Page 14: Product Labelling

    Product Labelling Key Product Labelling Product Labelling PORTADAVIT QUANTUM Safety Labels Serial Labels Product labelling The following labels must be present on your system and must be legible. 1. Product Number Insert and secure the bolt before loading the system. 2.
  • Page 15 Product Identification & Inspection Record Notes PORTADAVIT QUANTUM Periodic Examination & Repair History Insert data from serial numbers found on product Marking into table here: The serial labels indicate: Date Inspected by Pass/Fail Corrective Action Comments The product identification number The product’s unique serial number The goods’...
  • Page 16 Notes Notes PORTADAVIT QUANTUM...
  • Page 17 All information herein is copyright protected by REID Lifting Ltd. All company and product names are Trade Mark and Trade Name protected and all REID Lifting Ltd. Product IPR is protected under Patents, Patents Pending and/or Design Rights.