Adjusting Method - Sony SEL100F28GM Service Manual

Interchangeable lens
Table of Contents

Advertisement

5-5-3. Method of Starting and Finishing
(1) Starting the E-Mount Lens Adjustment
*
Make sure to disconnect the AC adaptor after finishing the adjustment
(including the case when stops due to an error).
*
SeusEX will start when the E-Mount Lens Adjustment is started.
Procedure of Starting
1. Set the Shooting Mode of the camera to the P mode (Program
Auto), then turn the power on.
2. Start the E-Mount Lens Adjustment.
3. The camera selection window opens, and select "ILCE-5000".
4. Click the [Connect] button and check that the connection status
becomes "Connect".
[].[].[].[]
(2) Finishing the E-Mount Lens Adjustment
Procedure of Finishing
1. Click the [Disconnect] button and check that the connection
status becomes "Disconnect".
[].[].[].[]
2. Click the [] button on the upper right of the main window to
finish the E-Mount Lens Adjustment.
3. Turn off the power of camera.
4. Disconnect the AC adaptor.
5-5-4. Adjustment Method of Each Item
(1) Lens Device (S)
• Adjust the focusing ring and the aperture ring.
• Check the switch operation.
Subject
Operation on Lens side
Shooting Mode of the camera P mode (Program Auto)

Adjusting Method

1. Set the macro switching ring to "0.85m-∞".
2. Click the [Lens Device (S)] button in the Adjustment and Inspec-
tion.
3. The START screen is displayed, after the preparation of adjust-
ment is completed, press the ENTER key.
4. "MF ROTATION START" is displayed, press the ENTER key.
5. Rotate the focusing ring in continuation in one direction.
Focusing ring
5-24
SEL100F28GM
Not required
• Focusing ring
• Aperture ring
• Aperture click switch
• Focus hold button
• Focus mode switch
• Shake compensation switch
• Macro switching ring
– Continued on next page –

Advertisement

Table of Contents
loading

Table of Contents