Hioki 9593-03 Instruction Manual
Hioki 9593-03 Instruction Manual

Hioki 9593-03 Instruction Manual

Rs-232c interface for 3157 ac grounding hitester

Advertisement

Quick Links

9593-03
Instruction Manual
RS-232C INTERFACE
For 3157 AC GROUNDING HiTESTER
EN
Mar. 2022 Revised edition 1
*600629071*
9593C981-01 22-03H
HIOKI 9593C981-01

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 9593-03 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hioki 9593-03

  • Page 1 9593-03 Instruction Manual RS-232C INTERFACE For 3157 AC GROUNDING HiTESTER Mar. 2022 Revised edition 1 *600629071* 9593C981-01 22-03H HIOKI 9593C981-01...
  • Page 2: Table Of Contents

    4.1 0 Input Buffer ·· ·· ·· ·· ·· ·· ·· ·· ·· ·· ·· ·· ·· ·· ·· ·· ·· ·· ·· ·· ·· ·· · 1 6 4.11 Event Registers · · · · · · · · · · · · · · · · · · · · 1 7 9593C981-01 HIOKI 9593C981-01...
  • Page 3 HIOKI 9593C981-01...
  • Page 4: Introduction

    Introduction Thank you for purchasing this HIOKI "9593-03 RS-232C INTERFACE." To get the maximum performance from the unit, please read this manual first, and keep this at hand. This Instruction Manual provides information and warnings essential for operating this equipment in a safe manner and for maintaining it in safe operating condition.
  • Page 5 HIOKI 9593C981-01...
  • Page 6: Chapter 1 Before Use

    When the unit is delivered, check and make sure that it has not been damaged in transit. If the unit is damaged, or fails to operate according to the specifications, contact your dealer or HIOKI representative. (1) 9593-03 RS-232C INTERFACE (2) This instruction manual 1.
  • Page 7: Shipping Precautions

    If this is not available, use the following procedure. ( 1 ) Wrap the unit in plastic sheeting. ( 2 ) After wrapping cushioning material around the unit, pack it into a cardboard box, and then seal up the box with adhesive tape. 1.2 Shipping Precautions HIOKI 9593C981-01...
  • Page 8: Notes On Use

    If you do not do so, the communication conditions will not be changed to the new ones. RS-232C 9593-03 Always be sure to secure the cable to the unit by tightening up the fixing screws provided.
  • Page 9: Installing The Rs-232C Interface

    (I) Remove the fixing screws, and take off the blank panel. (2) Insert the 9593-03 RS-232C INTERFACE into the exposed slot in the rear of the unit in the figure below. (3) Push the 9593-03 firmly into place, and fix with the screws removed in step 1. /...
  • Page 10: Introduction To The Rs-232C Interface

    Overview 2.1 Introduction to the RS-232C Interface By connecting the 9593-03 RS-232C INTERFACE to the 3157 AC GROUNDING HiTESTER, it is possible to control all the functions of the main unit (except for powering on and off) via the RS-232C bus.
  • Page 11: Specifications

    Not provided Handshake Set using the DIP switches. Connector D-sub 9-pin male with #4-40 locking screws ◎ ◎ The connector on the 9593-03 is for terminal(DTE). Signal assignments and explanation Signal name Input/output SIgnal Common (U neon nected) Carrier detection...
  • Page 12: Chapter 3 Names Of Parts

    Chapter 3 Names of Parts 3.1 Controls and Connections ( 1) 3157 front panel ® 〇ス;RCO HIOKI 3'16アAC GROUNDING HffEBTER ll I n n r n n 25[/A 不 - - l . LI LI. I LI LI 9 O LI.Us 〇こo...
  • Page 13 HIOKI 9593C981-01...
  • Page 14: Chapter 4 Operation

    • When the 3157 soft start mode is enabled, its operation slows down at starting test. This may cause a communication error, depending on the preset baud rate. Bit 8 is fixed at "1" (on). Switching it will cause improper operation. • 4. 1 Setting the RS-232C Communication Conditions HIOKI 9593C981-01...
  • Page 15: Communication Methods By The Rs-232C

    It represents the response data for query messages from the 3157. Example :TIMER_ON (Test time is currently enabled.) C三) A space is represented by "_" in the examples. Program messages 三へ| 四ニ ゜ ゜ 畷 ← Response messages 4.2 Communication Methods by the RS-232C HIOKI 9593C981-01...
  • Page 16: Message Format

    Response messages generated by the 3157 are in long form and in upper case letters. Example :TIMER_ON ( Test time is currently enabled. ) C三) If an error occurs when the query message is received, the query does not produce response message. 4.3 Message Format HIOKI 9593C981-01...
  • Page 17: Headers

    ( Q uery message asking for the current enablement state of the test time) Response message when headers are on. :TIMER_ON ↑ ↑ ① ② ① :Header portion ② :Data portion Response message when headers are off. Data portion only 4.4 Headers HIOKI 9593C981-01...
  • Page 18: Data Formats

    The term "NRf format" includes all these three formats. When the 3157 is receiving it accepts NRf format, but when it is sending response messages it utilizes whichever one of the formats NRl to NR3 is indicated in the specified command. Examples :CONFigure:CURRent_25 :CONFigure:CURRent_ +25.012 :CONFigure:CURRent_0.0025E4 4.5 Data Formats HIOKI 9593C981-01...
  • Page 19: Delimiters

    Example :ADjust_ON (3) Data separator If a message has several data items, commas (,) are required as data separators for separating these data items from one another. Example :KEY_< first byte>, <second byte> 4. 7 Separators HIOKI 9593C981-01...
  • Page 20: Abbreviation Of Compound Commands

    Messages with particular headers can be executed without relation to the current path. Further, they have no effect upon the current path. With the 3157, there are 4 possible current paths: :CON Figure: :MEASure: :MEMory: :SYSTem: 4.8 Abbreviation of Compound Commands HIOKI 9593C981-01...
  • Page 21: Output Queue

    4.10 Input Buffer The 3157 has an input buffer of 300 bytes capacity. When more than 300 bytes of data are transmitted, when the buffer is full any subsequent bytes received will be ignored. 4. 10 Input Buffer HIOKI 9593C981-01...
  • Page 22: Event Registers

    This bit is set to 1 when a query error is detected by the output Bit 2 queue control. • When the data overflows the output queue. • When data in the output queue has been lost. Bit 1 Unused. Bit 0 Unused. 4. 11 Event Registers HIOKI 9593C981-01...
  • Page 23 HIOKI 9593C981-01...
  • Page 24 R e f Command Ex p lanation p a g e *CLS Clears event register. *ESR? Queries standard event status register (SESR). *IDN? Queries device ID. *RST Device initialization. *TST? Queries the result of the self-test. 5.1 Command Summary HIOKI 9593C981-01...
  • Page 25 HIOKI 9593C981-01...
  • Page 26 HIOKI 9593C981-01...
  • Page 27 Specifies what types of error may occur. Any spelling error in a message results in a command error. C三) For details of each function, refer to the instruction manual for the 3157 unit. 5.2 Format of Command Explanations HIOKI 9593C981-01...
  • Page 28 Second field Model name Third field Serial number (Not used - always zero) Fourth field Software version Example Response HIOKl,3157,0,V01.01 Error If the response message is longer than 300 bytes, a query error is generated. 5.3 Particular Commands HIOKI 9593C981-01...
  • Page 29 HIOKI 9593C981-01...
  • Page 30 <data> ON/OFF (character data) Example Response If headers are on :ADJUST ON If headers are off Error If the response message is longer than 300 bytes, a query error is generated. 5.4 Commands Specific to the 3157 HIOKI 9593C981-01...
  • Page 31 HIOKI 9593C981-01...
  • Page 32 HIOKI 9593C981-01...
  • Page 33 HIOKI 9593C981-01...
  • Page 34 HIOKI 9593C981-01...
  • Page 35 HIOKI 9593C981-01...
  • Page 36 HIOKI 9593C981-01...
  • Page 37 HIOKI 9593C981-01...
  • Page 38 HIOKI 9593C981-01...
  • Page 39 HIOKI 9593C981-01...
  • Page 40 HIOKI 9593C981-01...
  • Page 41 HIOKI 9593C981-01...
  • Page 42 HIOKI 9593C981-01...
  • Page 43 HIOKI 9593C981-01...
  • Page 44 HIOKI 9593C981-01...
  • Page 45 HIOKI 9593C981-01...
  • Page 46 HIOKI 9593C981-01...
  • Page 47 HIOKI 9593C981-01...
  • Page 48 HIOKI 9593C981-01...
  • Page 49 HIOKI 9593C981-01...
  • Page 50 HIOKI 9593C981-01...
  • Page 51 HIOKI 9593C981-01...
  • Page 52 HIOKI 9593C981-01...
  • Page 53 HIOKI 9593C981-01...
  • Page 54 HIOKI 9593C981-01...
  • Page 55 HIOKI 9593C981-01...
  • Page 56 HIOKI 9593C981-01...
  • Page 57 HIOKI 9593C981-01...
  • Page 58 HIOKI 9593C981-01...
  • Page 59 HIOKI 9593C981-01...
  • Page 60 HIOKI 9593C981-01...
  • Page 61 HIOKI 9593C981-01...
  • Page 62 (4) Test time and test time elapsed 口.ロ ロロ.ロ ロロロ.ロ Two, three or four digits ( in NR2 format ) (5) Number of test data ロ ロロ One or two digits ( in NRl format ) 5.5 Response Format for Queries as Numerical Value HIOKI 9593C981-01...
  • Page 63 I nput buff e . . ● * 2 Event registers . . Current path Headers on/off Measurement resister *1: When the power is turned on, item is discriminated. *2: Except the PON bit (bit 7) 5.6 Initialization Items HIOKI 9593C981-01...
  • Page 64 3157. instant that the controller reads it in. Service If damage is suspected, read the "Troubleshooting" section to remedy the problem. If this does not help you, contact your authorized Hioki distributor or reseller. HIOKI 9593C981-01...
  • Page 65 HIOKI 9593C981-01...
  • Page 66 HIOKI 9593C981-01...

Table of Contents