2) Adjustment of the
Closing Speed
Damping Force
© DICTATOR Technik GmbH • Gutenbergstr. 9 • 86356 Neusäß • Germany
Tel. +49(0)821-24673-0 • Fax +49(0)821-24673-90 • E-mail info@dictator.de • 20200708
E) Adjustment of the Closing Force and Speed - cont.
In order to adjust the closing speed open the door completely.
Now adjust the closing speed during the closing of the door by turning
the adjustment screw at the radial damper (Allen key 5.5 mm or slotted
screw driver) (see ill. 16).
Turning it clockwise:
Turning it anticlockwise:
Now check whether the spring closes the door out of any open position
independent from how far it had been opened. If necessary increase
the tension of the spring or reduce the damping.
IMPORTANT: Pretension the spring only when the door is completely
open!
Adjustment screw for the
closing speed
Nm
2
1,5
1
0,5
0
0
50
100
Technical Manual
DICTAMAT 50 BK-Z
reduces the closing speed
increases the closing speed
Maximum adjustment LD50
LD50
LD50-2
Minimum adjustment LD50-2
150
200
U/min
Ill. 16
Ill. 17