Black Max BM905511 Operator's Manual page 18

5,500 watt generator
Table of Contents

Advertisement

Available languages

Available languages

CHECKING/ADDING FUEL
See Figure 10.
DANGER:
Risk of fire and serious burns: Never remove fuel cap
when unit is running. Shut off engine and allow the unit
to cool at least five minutes. Remove cap slowly.
WARNING:
Gasoline and its vapors are highly flammable and ex-
plosive. To prevent serious personal injury and property
damage, handle gasoline with care. Keep away from igni-
tion sources, handle outdoors only, do not smoke while
adding fuel, and wipe up spills immediately.
When adding gas to the generator, make sure the unit is sitting
on a flat, level surface. If the engine is hot, let the generator
cool for five minutes before adding gas. ALWAYS fill the fuel
tank outdoors with the machine turned off.
 Turn the fuel valve to the OFF position.
 Remove the fuel cap slowly.
 Fill the fuel tank to 1 in. below the top of the fuel neck.
 Replace and secure the fuel cap.
WARNING:
Always shut off engine before fueling. Never remove fuel
cap or add fuel to a machine with a running or hot engine.
Make sure the unit is sitting on a flat, level surface and
only add fuel outdoors. If the engine is hot, let the unit cool
for at least five minutes before adding fuel. After fueling,
immediately replace fuel cap and tighten securely. Move
at least 30 ft. from refueling site before starting engine. Do
not smoke and stay away from open flames and sparks!
Failure to follow these instructions could result in a fire
and cause serious personal injury.
NOTE: Always use unleaded gasoline with a pump octane
rating of 86 or higher. Never use old, stale, or contaminated
gasoline, and do not use an oil/gas mixture. Do not allow dirt
or water into the fuel tank. Do not use E85 fuel.
OPERATION
STARTING THE ENGINE
See Figures 11 - 13.
NOTICE:
On a level surface with the engine off, check the lubricant
level before each use of the generator.
NOTE: If location of generator is not level, the unit may not
start or may shut down during operation.
 Unplug all loads from the generator.
 Turn the fuel valve to the ON position.
 Move the choke lever left to the START position.
NOTE: If engine is warm or the temperature is above
50˚F, move the choke lever right to the RUN position.
 Pull the recoil starting grip until the engine runs.
NOTE: Do not allow the grip to snap back after starting;
return it gently to its original place.
 Allow the engine to run for 15–30 seconds, then move
the choke to the RUN position.
STOPPING THE ENGINE
See Figure 13.
To stop the engine under normal operating conditions:
 Remove any load from the generator.
 Turn the fuel valve to the OFF position.
 Press and hold the STOP switch until the engine stops.
To stop the unit quickly in an emergency:
 Press and hold the STOP switch until the engine stops.
WARNING:
While operating and storing, keep at least 3 feet of clear-
ance on all sides of this product, including overhead.
Allow a minimum of 30 minutes of "cool down" time be-
fore storage. Heat created by muffler and exhaust gases
can be hot enough to cause serious burns and/or ignite
combustible objects.
MOVING THE GENERATOR
See Figure 14.
 Turn off the generator.
 Raise the handle to the up position.
 Disconnect any equipment that is plugged into the
generator.
 Verify the fuel valve is in the OFF position.
Page 14 — English

Advertisement

Table of Contents
loading