Questions and answers

Summary of Contents for kosmek JVA0100

  • Page 1 Aut o  Cou ple r JV A010 0 / J V B0 1 0 0 Mo de l    ...
  • Page 2: Action Description

    Comparison of Auto Coupler Connected Dimensions Range Fluid JVB  (Pressure Source Side) mm 2 Min. Passage Area: ② When Using with Screw Locator (VXF/VXE) Secured Passage Area   The reaction force (spring force) is generated when setting up  Base Pallet   the pallet because the stroke of ''Screw Locator'' is 0.2 ~ 0.3mm. Equal to Air Hose I.D.φ3.2 JVB0100 JVA0100   If using a light pallet, it may be lifted up when tightening. In case of the min. depth of the mounting hole.  10.5 10.5 1 MPa Minimum Size M o de l    or less JVA0100/  soft seal is provided Moreover, for the pressure source side. JVB0100 Air Leak Prevention & Energy Saving...
  • Page 3 Action Action Model No. Model No. Exteral Exteral Auto Coupler  JVA0100 / JVB0100 Features Features Specifications Specifications Cautions Cautions  For Air / Vacuum (Operating Pressure Range  :  lower than 1MPa) model Description Description Indication Indication Dimensions Dimensions Model No. Indication External Dimensions (JVA0100-H / JVB0100-H) Machining Dimensions for  Mounting Hole (JVA0100-H) φ10.2 M12×1 Thread J V B 01 0 0 - H φ7.6...
  • Page 4 Features Features Specifications Specifications Cautions Cautions  Cautions m od e l   Description Description Indication Indication Dimensions Dimensions Notes for Usage (JVA0100/JVB0100) Cautions    1. Do not connect or disconnect the auto coupler under pressure. (Refer to the following Circuit Reference.) ●  Installation Notes ●  Notes on Handling   2. Do not connect the coupler when contaminants are adhered on each connecting surface. 1)  Check the Usable Fluid 1)  It should be operated by qualified personnel.     When there are cutting chips or coolant, install a cover, or remove all contaminants with air blow.  ●  Please supply filtered clean dry air.  ●  The hydraulic machine and air compressor should be operated  ●  Oil supply with a lubricator, etc. is unnecessary.  ...
  • Page 5 K O S M E K   L T D . ▶    h t tp: / /w w w .ko s me k .com/ HEAD OFFICE 1-5, 2-chome, Murotani, Nishi-ku, Kobe-city, Hyogo, Japan  651-2241 TEL.+81-78-991-5162 FAX.+81-78-991-8787 United States of America KOSMEK (USA) LTD. SUBSIDIARY 650 Springer Drive, Lombard, IL 60148 USA TEL. +1-630-620-7650 FAX. +1-630-620-9015 MEXICO KOSMEK USA Mexico Office REPRESENTATIVE OFFICE Av. Santa Fe 103, Int. 59, col. Santa Fe Juriquilla, Queretaro, QRO, 76230, Mexico TEL. +52-1-55-3044-9983...