ATTENTION
If need suspending installation, the installation bracket should accord with all technical
requirements. The installation wall should be strong enough or actions to reinforce should be
taken. The connection between bracket and wall, bracket and the air conditioner should be firm,
stable and reliable. In case of any doubts or uncertainty do not attempt to install the unit but
have the support calculated and engineered by a skilled engineer.
5. P OSSIBILITIES FOR INSTALLING THE PIPING FROM THE INTERIOR UNIT TO
THE EXTERIOR UNIT.
G
NOTE ON PIPING ANGLE
Refrigerant piping can exit the indoor unit from Left-rear side (when you're facing the back of
the unit)
6. M OUNTING THE INSTALLATION PLATE AND MAKING THE PIPING
FEEDTHROUGH.
6.1 Mounting the installation plate of the interior unit.
WARNING!
Use a pipe detector to detect electrical conduits and pipes in the wall before drilling the required
holes to prevent unnecessary damage to the wall or dangerous situations.
a.
Fit the installation plate  horizontally on structural parts of the wall with spaces around the instal-
lation plate. See figure 8.
b.
If the wall is made of brick, concrete or the like, drill eight (8) 5mm diameter holes in the wall. Insert
clip anchor  for appropriate mounting screws .
c.
Fit the installation plate  on the wall with eight (8) type "A" screws .
G
REMARK
Mount the mounting plate and drill the holes in the wall corresponding to the material of the
wall and the mounting points on the mounting plate in question (dimensions are in "mm" unless
otherwise indicated).