Campbell CS500-LC Instruction Manual

Campbell CS500-LC Instruction Manual

Temperature and relative humidity probe for metdata1

Advertisement

Quick Links

CS500-LC Temperature and
Relative Humidity Probe
for MetData1
4/97
C o p y r i g h t
( c )
1 9 9 5 - 1 9 9 7
C a m p b e l l
S c i e n t i f i c ,
I n c .

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CS500-LC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Campbell CS500-LC

  • Page 1 CS500-LC Temperature and Relative Humidity Probe for MetData1 4/97 C o p y r i g h t ( c ) 1 9 9 5 - 1 9 9 7 C a m p b e l l S c i e n t i f i c ,...
  • Page 2: Warranty And Assistance

    (12) months from date of shipment unless specified otherwise. Batteries have no warranty. CAMPBELL SCIENTIFIC, INC.'s obligation under this warranty is limited to repairing or replacing (at CAMPBELL SCIENTIFIC, INC.'s option) defective products. The customer shall assume all costs of removing, reinstalling, and shipping defective products to CAMPBELL SCIENTIFIC, INC.
  • Page 3: Installation

    CS500-LC TEMPERATURE AND RELATIVE HUMIDITY PROBE FOR METDATA1 207 probes, can be converted to a 41002 with 1. GENERAL P/N 6638. The Model CS500 temperature and relative humidity probe uses a 1000 Ω PRT (DIN 43760B) to measure temperature and a Vaisala capacitive humidity sensor (INTERCAP) to measure relative...
  • Page 4: Datalogger Programming

    CS500-LC TEMPERATURE AND RELATIVE HUMIDITY PROBE FOR METDATA1 3. CONNECTION The CS500 cable is attached to the MetData1 connector labeled #1. Ensure internal jumper #1 is open as shown in Figure 5. Default CS800 FIGURE 5. MetData1 Jumper Configuration FIGURE 3. CS500 and 41002 Radiation Shield on a CM6/CM10 Tripod Mast 4.
  • Page 5: Maintenance And Calibration

    CS500-LC TEMPERATURE AND RELATIVE HUMIDITY PROBE FOR METDATA1 Volt (SE) 5. MAINTENANCE AND CALIBRATION The CS500 probe requires minimal 2500 mV 60 Hz rejection maintenance. Check monthly to make sure the Range radiation shield is free from debris. The white IN Chan screen on the sensor’s end should also be...
  • Page 6 CS500-LC TEMPERATURE AND RELATIVE HUMIDITY PROBE FOR METDATA1 This is a blank page.
  • Page 7 This is a blank page.
  • Page 8: Campbell Scientific Companies

    Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com info@campbellsci.com Campbell Scientific Africa Pty. Ltd. (CSAf) PO Box 2450 Somerset West 7129 SOUTH AFRICA www.csafrica.co.za sales@csafrica.co.za Campbell Scientific Australia Pty. Ltd. (CSA)

Table of Contents