Configuration For Utilizing Four Flow Meters For Large Round Pipes - Sage RIO SIX Instruction Manual

Thermal gas mass flow meter
Table of Contents

Advertisement

16
S A G E M E T E R I N G , I N C .
CONFIGURATION FOR UTILIZING FOUR (4) SAGE INSERTION MASS FLOW METERS FOR LARGE ROUND
PIPES OR DUCTS LARGER THAN 36" TO MINIMIZE EFFECTS OF VARYING FLOW PROFILES
(It is recommended that Factory be contacted to assist with applications of this nature)
3/4" NPT explosion
proof plug
The outputs of the four meters will be averaged
by customer's PLC or other method to improve
overall accuracy in measuring the flow rate. (For
medium sized round pipes [18" to 36"], two meters,
REV. 10-SIX/SRX
3/4" NPT for
remote cable
O p e r a t i o n s a n d I n s t r u c t i o n M a n u a l
3/4" NPT
for User Entry
3/4" NPT explosion
proof plug
3/4" NPT for
probe support
on the opposite side of the same diameter, may be
sufficient [insert parallel to an upstream 90 degree
bend for optimal benefit.]) Note, in this configura-
tion, all sensors need to be averaged.
ATEX approved cable
gland/strain relief is
provided with unit
The cable provided
is for bench testing
ONLY – it is NOT
approved