Acorn NEO-METRO SLAB-EDGE 3802 Installation, Operation & Maintenance Manual

Advertisement

Quick Links

SLAB-EDGE
MODEL 3802
®
CORTERRA
ADA/OBC COMPLIANT
WASH BASIN

TABLE OF CONTENTS

Prior to Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Accessibility Comparison . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Dimensional Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Rough-Ins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 - 12
Finished Layouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 - 15
Cleaning and Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Components & Repair Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 - 18
REQUIRED ITEMS FOR INSTALLATION - NOT SUPPLIED
Chalk Line
?
Hammer
?
Carpenters Level
?
1/2" NPS Supply Angle Stops
?
7/16" Hex Wrench
?
Plumbers Putty
?
Part #: 6216-011-000
®
TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863
Page 1 of 18
INSTALLATION, OPERATION
& MAINTENANCE MANUAL
Teflon Tape
?
9/16" (8 Count) Fixture Wall Anchors and
?
Anchoring Hardware (and Appropriate Tools)
9/32" (10 Count) Fixture Wall Anchors and
?
Anchoring Hardware (and Appropriate Tools)
N E O - M E T R O
15125 Proctor Ave. • City of Industry, CA 91746 USA
TF 800.488.8999 • PH 626.336.4561 • FX 626.961.2200
®
b y A C O R N
Acorn Engineering Company
NEO-METRO FIELD SERVICE
Revised A: 10/24/22
®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NEO-METRO SLAB-EDGE 3802 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Acorn NEO-METRO SLAB-EDGE 3802

  • Page 1: Table Of Contents

    ® N E O - M E T R O b y A C O R N Acorn Engineering Company 15125 Proctor Ave. • City of Industry, CA 91746 USA TF 800.488.8999 • PH 626.336.4561 • FX 626.961.2200 NEO-METRO FIELD SERVICE TOLL FREE 800-743-8259 •...
  • Page 2: Prior To Installation

    INSTALLATION, OPERATION & MAINTENANCE MANUAL Important: Some options may slightly alter installation. To ensure proper installation review the manual thoroughly and verify rough-ins before beginning any work. File this manual with the owner or maintenance personnel upon completion of installation. Industry standard wall backing, for wall hung fixtures, is required.
  • Page 3: Accessibility Comparison

    INSTALLATION, OPERATION & MAINTENANCE MANUAL ACCESSIBILITY COMPARISONS 22" 22" 3 3 4 " 3 3 4 " 17" 17" 34" RIM 31" RIM 9" 27" 27" 9" PROFILE PROFILE ADA ages ADA ages Adult 6 thru 12 6 thru 12 22"...
  • Page 4: Dimensional Data

    INSTALLATION, OPERATION & MAINTENANCE MANUAL DIMENSIONAL DATA 22" 56" 17" NEO-METRO FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863 Part #: 6216-011-000 Page 4 of 18 Revised A: 10/24/22...
  • Page 5: Rough-Ins

    INSTALLATION, OPERATION & MAINTENANCE MANUAL ROUGH-IN DIMENSIONS 21 1 2 " ADA (Adult) 17" [432] [546] 4 3 4 " 5" [127] [121] 5 1 2 " [140] 6" 10" [152] 11" [254] [279] 34" [864] ADA ADULT 34" [864] OBC 34"...
  • Page 6 INSTALLATION, OPERATION & MAINTENANCE MANUAL OPTIONAL -MC MOUNTING CARRIER Note: Adequate wall depth is the responsibility of Contractor/Architect. Minimum 6” stud wall required to conceal optional -MC Mounting Carrier plus consideration for fixture Water Supply and Waste Piping. " [70] 4"...
  • Page 7 INSTALLATION, OPERATION & MAINTENANCE MANUAL FIXTURE ANCHORING NOTE: FIXTURE WEIGHT IS 126 LBS. Locate and mount the mounting bracket to a finished wall. Locate and install P-Trap enclosure anchors provide by others. NOTE: It may be advantageous to install to the deck, faucets, 1/4"...
  • Page 8 INSTALLATION, OPERATION & MAINTENANCE MANUAL WASTE PLUMBING Install grid strainer and close elbow to basin bowl using plumber's putty. 1. Grid Strainer w/ 1-1/2" -16 UNE Threads 2. Rubber Gasket 3. Flat Fiber Washer 4. 1-1/2" -16 UNI Rough Chrome Brass Jam Nut 5.
  • Page 9: Installation

    INSTALLATION, OPERATION & MAINTENANCE MANUAL SPOUT INSTALLATION 1. Assemble spout to deck securing it with nut. 2. Connect 1/4” O.D. PE tubing from valve to Union Push-In Connection. Washer Push-In Connection Ø1/4" OD PE Tubing O-RING O-RING COLLET PUSH-IN FITTING INSTALLATION NOTE: FITTINGS AND TUBE SHOULD BE KEPT TUBE STOP CLEAN, BAGGED AND UNDAMAGED PRIOR TO...
  • Page 10 INSTALLATION, OPERATION & MAINTENANCE MANUAL VALVE INSTALLATION & ADJUSTMENT IMPORTANT Valve Assembly Installation: NOTE: Installation should be in accordance with Flush supply lines of all foreign material such accepted plumbing practices. as pipe dope, pipe chips, solder, sand etc. before making up supply connections. 1) Locate suitable place for mounting the valve assembly.
  • Page 11 INSTALLATION, OPERATION & MAINTENANCE MANUAL HAND OPERATION & CONNECTIONS 3802-H-MXTP DIAGRAM (SHOWN FOR REFERENCE) 1/8" O.D. AIR TUBE Timing Screw 1/4" O.D. WATER LINE To adjust timing, turn timing screw. Ferrule Nut Do not over tighten ferrule nuts. Turn timing screw clockwise to increase timing.
  • Page 12 Mounting Some soaps contain corrosive additives that can cause rust in Bracket 1-1/4" soap dispensers. Acorn Engineering Company recommends user/ maintenance personnel review MSDS reports of soap and possible corrosive additives noted. Install soap reservoir to wall inside P-Trap enclosure using mounting brackets provided as shown.
  • Page 13: Finished Layouts

    INSTALLATION, OPERATION & MAINTENANCE MANUAL FINISHED LAYOUTS (SHOWN FOR REFERENCE) MODEL #3802-H-PDM MODEL #3802-WD04-PDM NEO-METRO FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863 Part #: 6216-011-000 Page 13 of 18 Revised A: 10/24/22...
  • Page 14: Troubleshooting

    INSTALLATION, OPERATION & MAINTENANCE MANUAL TROUBLE SHOOTING FOR 9 VOLT DC SENSOR OPERATED VALVES Normal Valve Function: 9 Volt DC sensor operated valve has flow time of 90 seconds maximum. To reactivate, the user must move out of and return to the sensing area. CONDITION: WATER DOES NOT FLOW Indicators Probable Cause...
  • Page 15 INSTALLATION, OPERATION & MAINTENANCE MANUAL TROUBLE SHOOTING FOR OPTIONAL PUSHBUTTON OPERATED VALVES Normal Valve Function: Hand pushbutton operated valve has an adjustable flow time from 5 to 60 seconds. CONDITION: WATER DOES NOT FLOW Probable Cause Solution Water main closed. Open water main.
  • Page 16: Cleaning And Maintenance

    Always follow cleaner product For more serious physical damage caused by vandals, an directions provided. Afterwards, using a soft, non-abrasive Acorn Solid Surface Repair Kit is available. Contact the cloth, wipe surfaces with stainless steel cleaner/polish. factory for details. Refer to drawing #9927-160-002.
  • Page 17: Components & Repair Parts

    INSTALLATION, OPERATION & MAINTENANCE MANUAL COMPONENTS & REPAIR PARTS Diagram Description Part No. -SO VALVE AND SPOUT DETAILS 3802-SO Binho Industrial Sensor Operated Spout 2992-066-000 9VDC provided with Power Supply and Battery Pack 3802-SO-MXTP/3802-WD04-MXTP/ 3802-H0-MXTP/3802-H1-MXTP/ 7802-401-001 3802-H34-MXTP ST7069-12, 1/2” NPSM, Mixing Valve -WD04 VALVE AND SPOUT DETAILS 3802-WD04 3040-091-000...
  • Page 18 INSTALLATION, OPERATION & MAINTENANCE MANUAL COMPONENTS & REPAIR PARTS Diagram Description Part No. -PDM SOAP OPTION Soap Filler Assembly 1391-008-001 WASTE ASSEMBLY Grid Strainer w/ Close Elbow 4926-062-001 P-Trap Waste Assembly 4970-040-003 ENCLOSURES Trap Enclosure 6216-200-002 MOUNTING HARDWARE Mounting Bracket 6216-204-199 Stainless Steel, Hex Head, Cap Screw, 0206-004-000...