Acorn MERIDIAN 3802 Installation, Operation & Maintenance Manual

Acorn MERIDIAN 3802 Installation, Operation & Maintenance Manual

Wash basin

Advertisement

Please visit www.acorneng.com
for most current specifications.
MERIDIAN
MODEL 3802
CORTERRA
ADA/OBC COMPLIANT
WASH BASIN

TABLE OF CONTENTS

Prior to Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Accessibility Comparison . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Dimensional Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Rough-Ins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 - 12
Finished Layouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 - 14
Troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 - 16
Cleaning and Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Components & Repair Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 - 21
Warranty Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
REQUIRED ITEMS FOR INSTALLATION - NOT SUPPLIED
Chalk Line
?
Hammer
?
Carpenters Level
?
1/2" NPS Supply Angle Stops
?
7/16" Hex Wrench
?
Plumbers Putty
?
Part #: 6216-011-000
INSTALLATION, OPERATIONS & MAINTENANCE MANUAL
TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863
Teflon Tape
?
9/16" (8 Count) Fixture Wall Anchors and
?
Anchoring Hardware (and Appropriate Tools)
9/32" (10 Count) Fixture Wall Anchors and
?
Anchoring Hardware (and Appropriate Tools)
A C O R N E N G I N E E R I N G C O M P A N Y
P. O . B O X 3 5 2 7 • C I T Y O F I N D U S T R Y, C A 9 1 7 4 4 U . S . A .
T O L L F R E E 8 0 0 - 4 8 8 - 8 9 9 9 : : L O C A L 6 2 6 - 3 3 6 - 4 5 6 1
FA X 6 2 6 - 9 6 1 - 2 2 0 0 : : w w w. a c o r n e n g . c o m
ACORN ENGINEERING FIELD SERVICE
Page 1 of 22
Date: 01/10/17

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MERIDIAN 3802 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Acorn MERIDIAN 3802

  • Page 1: Table Of Contents

    FA X 6 2 6 - 9 6 1 - 2 2 0 0 : : w w w. a c o r n e n g . c o m ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863...
  • Page 2: Prior To Installation

    120VAC/9VDC, 100mA plug-in transformer. NOTE: Receptacle(s) must be wired to a GFCI protected circuit. Fixture must be earth grounded per N.E.C. (National Electrical Code). ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863 Part #: 6216-011-000...
  • Page 3: Accessibility Comparison

    3 3 4 " 17" 17" 34" RIM 33" RIM 9" 9" PROFILE BCBC (British Colombia Building Code) (Ontario Building Code) ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863 Part #: 6216-011-000 Page 3 of 22 Date: 01/10/17...
  • Page 4: Dimensional Data

    INSTALLATION, OPERATIONS & MAINTENANCE MANUAL Please visit www.acorneng.com MERIDIAN 3802 for most current specifications. DIMENSIONAL DATA 22" 56" 17" ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863 Part #: 6216-011-000 Page 4 of 22 Date: 01/10/17...
  • Page 5: Rough-Ins

    H - Wall Anchoring Ø9/16” Mounting Hole, Support Bracket Mounting, 2 Places. I - Wall Anchoring Ø3/8” x 3/4” Long, Trap Cover Mounting Slots, 2 Places. ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863 Part #: 6216-011-000...
  • Page 6 When trap closure is in the closed position, secure trap closure by securing cover catch to bottom of counter deck. ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863 Part #: 6216-011-000 Page 6 of 22...
  • Page 7 AS NEEDED 7 1 2 " HINT: Teflon tape is recommended on all threaded waste and supply connections. ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863 Part #: 6216-011-000 Page 7 of 22 Date: 01/10/17...
  • Page 8: Installation

    While holding the collet in, pull on the PE tubing to remove from the push-in fitting. COLLET ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863 Part #: 6216-011-000 Page 8 of 22...
  • Page 9: Temperature Adjustment

    STEM temperature. WARMER 4) Tighten locknut to prevent accidental or unauthorized temperature adjustment. 5) Re-check outlet temperature. ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863 Part #: 6216-011-000 Page 9 of 22 Date: 01/10/17...
  • Page 10 Transformer must be plugged into a GFI protected circuit. Fixture must be earth grounded per N.E.C. or applicable codes. ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863 Part #: 6216-011-000 Page 10 of 22 Date: 01/10/17...
  • Page 11 Leave a minimum 1/4” of polyethylene tubing through the Ferrule Nut on the pushbutton assembly. This is necessary to ensure proper tubing connection. ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863 Part #: 6216-011-000 Page 11 of 22...
  • Page 12 Mounting Some soaps contain corrosive additives that can cause rust in Bracket 1-1/4" soap dispensers. Acorn Engineering Company recommends user/ maintenance personnel review MSDS reports of soap and possible corrosive additives noted. Install soap reservoir to wall inside trap enclosure using mounting brackets provided as shown.
  • Page 13: Finished Layouts

    Please visit www.acorneng.com MERIDIAN 3802 for most current specifications. FINISHED LAYOUTS (SHOWN FOR REFERENCE) MODEL #3802-AB09-SOS MODEL #3802-AB09-PDM ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863 Part #: 6216-011-000 Page 13 of 22 Date: 01/10/17...
  • Page 14 Please visit www.acorneng.com MERIDIAN 3802 for most current specifications. FINISHED LAYOUTS (SHOWN FOR REFERENCE) MODEL #3802-SO-SOS MODEL #3802-H-PDM ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863 Part #: 6216-011-000 Page 14 of 22 Date: 01/10/17...
  • Page 15: Troubleshooting

    Disconnect solenoid and Solenoid polarity crossed. flashes when hands are within reverse polarity. range and water shuts off. ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863 Part #: 6216-011-000 Page 15 of 22 Date: 01/10/17...
  • Page 16 Air leaks from 1/8" O.D. tubing or fittings. Replace damaged tubing or fitting. Pushbutton air diaphragm leaks. Replace pushbutton air diaphragm. ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863 Part #: 6216-011-000 Page 16 of 22...
  • Page 17 Always follow cleaner product For more serious physical damage caused by vandals, an directions provided. Afterwards, using a soft, non-abrasive Acorn Solid Surface Repair Kit is available. Contact the cloth, wipe surfaces with stainless steel cleaner/polish. factory for details. Refer to drawing #9927-160-002.
  • Page 18: Components & Repair Parts

    ¼"-20 x 1" Thick Fender Washer 0332-004-000 SPOUTS 2993-400-001 Stern Easy E/B Sensor Operated Spout 9VDC 2993-410-001 Stern Easy E/B Hand Operated Spout ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863 Part #: 6216-011-000 Page 18 of 22 Date: 01/10/17...
  • Page 19 Solenoid Extension, 9 Volt, 2FT, White 0711-430-001 Solenoid Extension, 9 Volt, 2FT, Red 0711-431-001 ACORN ENGINEERING FIELD SERVICE ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863 TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863...
  • Page 20 ENCLOSURES Trap Enclosure (3803) 6216-200-002 Mounting Bracket 3803 Mounting Bracket 6216-204-199 -PDM SOAP OPTION Soap Filler Assembly 1391-008-001 ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863 Part #: 6216-011-000 Page 20 of 22 Date: 01/10/17...
  • Page 21 Optional 2-Station, Hand Operated, 2595-612-001 Single Temp, Metering Valve Assembly 7802-101-001 ST70-12 1/2” NPT Mixing Valve ST70-12 Valve Bracket Assembly 7842-020-001 ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863 Part #: 6216-011-000 Page 21 of 22 Date: 01/10/17...
  • Page 22: Warranty Information

    Where claims for defects are made, the defective part or parts shall be delivered to the company, prepaid, at City of Industry, California for inspection. Acorn will not be liable for the cost of repairs, alterations or replacement, or for any expense connected therewith made by the owner or his agents, except upon written authority from the Acorn City of Industry office.

Table of Contents