Download Print this page
Acorn Meridian Corterra 3751 Installation, Operation & Maintenance Manual

Acorn Meridian Corterra 3751 Installation, Operation & Maintenance Manual

Ada-compliant wash basin

Advertisement

Quick Links

Please visit www.acorneng.com
for most current specifications.
MERIDIAN
MODEL
3751
®
CORTERRA
ADA-COMPLIANT
WASH BASIN

TABLE OF CONTENTS

Prior to Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Accessibility Comparison . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Dimensional Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Rough-Ins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 - 6
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 - 16
Piezo Adjustment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 - 19
Troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 - 21
Cleaning and Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Components & Repair Parts. . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 -26
Warranty Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
REQUIRED ITEMS FOR INSTALLATION - NOT SUPPLIED
Chalk Line
?
Hammer
?
Carpenters Level
?
1/2" NPS Supply Angle Stops
?
7/16" Hex Wrench
?
Plumbers Putty
?
Part #: 6215-369-000
INSTALLATION, OPERATIONS & MAINTENANCE MANUAL
®
TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863
Teflon Tape
?
3/8" (12 Count) Fixture Wall Anchors and
?
Anchoring Hardware (and Appropriate Tools)
#10 (10 Count) Fixture Wall Anchors and
?
Anchoring Hardware (and Appropriate Tools)
A C O R N E N G I N E E R I N G C O M P A N Y
A C O R N E N G I N E E R I N G C O M P A N Y
P. O . B O X 3 5 2 7 • C I T Y O F I N D U S T R Y, C A 9 1 7 4 4 U . S . A .
P. O . B O X 3 5 2 7 • C I T Y O F I N D U S T R Y, C A 9 1 7 4 4 U . S . A .
T O L L F R E E 8 0 0 - 4 8 8 - 8 9 9 9 : : L O C A L 6 2 6 - 3 3 6 - 4 5 6 1
T O L L F R E E 8 0 0 - 4 8 8 - 8 9 9 9 : : L O C A L 6 2 6 - 3 3 6 - 4 5 6 1
FA X 6 2 6 - 9 6 1 - 2 2 0 0 : : w w w. a c o r n e n g . c o m
FA X 6 2 6 - 9 6 1 - 2 2 0 0 : : w w w. a c o r n e n g . c o m
ACORN ENGINEERING FIELD SERVICE
Date: 03/05/19

Advertisement

loading
Need help?

Need help?

Do you have a question about the Meridian Corterra 3751 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Acorn Meridian Corterra 3751

  • Page 1: Table Of Contents

    FA X 6 2 6 - 9 6 1 - 2 2 0 0 : : w w w. a c o r n e n g . c o m Part #: 6215-369-000 Date: 03/05/19 ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863...
  • Page 2: Prior To Installation

    NOTE: Receptacle(s) must be wired to a GFCI protected circuit. Fixture must be earth grounded per N.E.C. (National Electrical Code). Page 2 of 27 Part #: 6215-369-000 Date: 03/05/19 ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863...
  • Page 3: Accessibility Comparison

    22" 14 3 4 " 3" 20 5 8 " 33" RIM 5" PROFILE 12 3 8 " Page 3 of 27 Part #: 6215-369-000 Date: 03/05/19 ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863...
  • Page 4: Dimensional Data

    Please visit www.acorneng.com ® MERIDIAN 3751 for most current specifications. DIMENSIONAL DATA 22" 30" 20 5 8 " Page 4 of 27 Part #: 6215-369-000 Date: 03/05/19 ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863...
  • Page 5 E - Wall Anchoring for .219" Diameter x 3/8" Long, Enclosure Mounting Slots,10 Places. F - Valve Mounting Area. Page 5 of 27 Part #: 6215-369-000 Date: 03/05/19 ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863...
  • Page 6 E - Wall Anchoring for .219" Diameter x 3/8" Long, Enclosure Mounting Slots,10 Places. F - Valve Mounting Area. Page 6 of 27 Part #: 6215-369-000 Date: 03/05/19 ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863...
  • Page 7 E - Wall Anchoring for .219" Diameter x 3/8" Long, Enclosure Mounting Slots,10 Places. F - Valve Mounting Area. Page 7 of 27 Part #: 6215-369-000 Date: 03/05/19 ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863...
  • Page 8 NOTE: It may be advantageous to install to the deck, faucets, soap dispensers or other accessories prior to wall mounting. Page 8 of 27 Part #: 6215-369-000 Date: 03/05/19 ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863...
  • Page 9 1-1/2” P-Trap. 3 1 2 " 5 5 8 " 7 3 4 " Page 9 of 27 Part #: 6215-369-000 Date: 03/05/19 ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863...
  • Page 10: Installation

    While holding the collet in, pull on the PE tubing to remove from the push-in fitting. COLLET Page 10 of 27 Part #: 6215-369-000 Date: 03/05/19 ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863...
  • Page 11 TEMPERATURE STEM 4) Tighten locknut to prevent accidental or unauthorized temperature adjustment. WARMER 5) Re-check outlet temperature. Page 11 of 27 Part #: 6215-369-000 Date: 03/05/19 ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863...
  • Page 12 GFI protected TRANSFORMER circuit. Fixture must be earth grounded per N.E.C. or BLUE applicable codes. SOLENOID VALVE Page 12 of 27 Part #: 6215-369-000 Date: 03/05/19 ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863...
  • Page 13 Sensor Operation Battery Powered -SO SENSOR -PPZ PUSHBUTTON BLUE TRANSFORMER BLUE Acorn does not provide batteries for -BAT units. Each station requires (6) AA batteries. SOLENOID VALVE To service or install batteries remove access panel by removing (4) 10-32 x 3/4"...
  • Page 14 Leave a minimum 1/4” of polyethylene tubing through the Ferrule Nut on the pushbutton assembly. This is necessary to ensure proper tubing connection. Page 14 of 27 Part #: 6215-369-000 Date: 03/05/19 ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863...
  • Page 15 Position station enclosures 7 aligning mounting points and secure with installer provided hardware. Page 15 of 27 Part #: 6215-369-000 Date: 03/05/19 ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863...
  • Page 16 OPTIONAL ACCESSORY INSTALLATION & ASSEMBLY WARNING Some soaps contain corrosive additives that can cause rust in soap dispensers. Acorn Engineering Company recommends user/ maintenance personnel review MSDS reports of soap and possible corrosive additives noted. Install soap reservoir to wall inside trap enclosure using mounting brackets provided as shown.
  • Page 17 Page 17 of 27 Part #: 6215-369-000 Date: 03/05/19 ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863...
  • Page 18 20 sec added to the total timing cycle. x 20 = EQUALS Total timing cycle equals seconds Page 18 of 27 Part #: 6215-369-000 Date: 03/05/19 ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863...
  • Page 19 PIEZO PUSHBUTTON PROGRAMMING INDICATOR LED LIGHT TRANSPARENT EPOXY FILLING RED POWER CABLE BLACK SOLENOID CABLE Page 19 of 27 Part #: 6215-369-000 Date: 03/05/19 ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863...
  • Page 20: Troubleshooting

    Disconnect solenoid and Solenoid polarity crossed. flashes when hands are within reverse polarity. range and water shuts off. Page 20 of 27 Part #: 6215-369-000 Date: 03/05/19 ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863...
  • Page 21 Air leaks from 1/8" O.D. tubing or fittings. Replace damaged tubing or fitting. Pushbutton air diaphragm leaks. Replace pushbutton air diaphragm. Page 21 of 27 Part #: 6215-369-000 Date: 03/05/19 ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863...
  • Page 22 Always follow cleaner product For more serious physical damage caused by vandals, an directions provided. Afterwards, using a soft, non-abrasive Acorn Solid Surface Repair Kit is available. Contact the cloth, wipe surfaces with stainless steel cleaner/polish. factory for details. Refer to drawing #9927-160-002.
  • Page 23: Components & Repair Parts

    ¼"-20 x 1/2" Long ¼"-20 x 1" Thick Fender Washer 0332-004-000 SPOUTS Stern Easy E/B Sensor Operated Spout 2993-400-001 9VDC Page 23 of 27 Part #: 6215-369-000 Date: 03/05/19 ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863...
  • Page 24 Push Button Assembly -PPZ Programmable Piezo Pushbutton 0709-067-001 ELECTRONIC HARDWARE 9 VDC Plug-In Transformer 0711-410-001 2563-326-001 9 VDC Solenoid Page 24 of 27 Part #: 6215-369-000 Date: 03/05/19 ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863...
  • Page 25 Grid Strainer w/ Close Elbow 4926-063-001 P-Trap Waste Assembly 4970-040-002 ENCLOSURES Trap Enclosure 6215-120-199 -PDM SOAP OPTION Soap Filler Assembly 1391-008-001 Page 26 of 27 Part #: 6215-369-000 Date: 03/05/19 ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863...
  • Page 26 Optional 1-Station,9VDC Solenoid, 2598-331-001 Single Temp Valve Assembly Optional 1-Station, Hand Operated, 2598-301-001 Single Temp, Metering Valve Assembly Page 25 of 27 Part #: 6215-369-000 Date: 03/05/19 ACORN ENGINEERING FIELD SERVICE TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863...
  • Page 27: Warranty Information

    Where claims for defects are made, the defective part or parts shall be delivered to the company, prepaid, at City of Industry, California for inspection. Acorn will not be liable for the cost of repairs, alterations or replacement, or for any expense connected therewith made by the owner or his agents, except upon written authority from the Acorn City of Industry office.