REQUIRED ITEMS FOR INSTALLATION – NOT SUPPLIED
7/16" Hex Wrench
Plumbers Putty
Teflon Tape
Slotted Screwdriver (for Metering Adjustment)
Socket and Driver for Center Reject Bit
3/8" Fixture Anchoring Hardware (and Appropriate Tools)
TRUE SIZE
TRUE SIZE
TRUE SIZE
TRUE SIZE
L1000802
MERIDIAN MODEL# 3792
CORTERRA ADA-COMPLIANT
WASHFOUNTAIN
0152-006-000
10-32 UNF x 3/4" Center
Reject Hex Socket Flat
Head Screw – Qty. 12
0206-002-000
1/4"-20 UNC x 1" Hex
Head Cap Screw – Qty. 4
0206-004-000
1/4"-20 UNC x 1/2" Hex
Head Cap Screw – Qty. 4
0296-025-199
Allen Head Bit With
Center Reject – Qty. 1
Acorn Engineering Company
1 5 1 2 5 P r o c t o r A v e n u e
C i t y o f I n d u s t r y • C A • U S A • 9 1 7 4 4 - 0 5 2 7
P h o n e : 8 0 0 . 4 8 8 . 8 9 9 9
Faxback: 888.226.7624 Web Site: www.acorneng.com
F i e l d S e r v i c e 8 0 0 . 7 4 3 . 8 2 5 9
1/4" Lock Washer – Qty. 12
(For –ST option – Qty. 16)
1/4" Flat Washer – Qty. 8
(For –ST option – Qty. 12)
0331-031-000
1/4" Fender Washer
Qty. 4
1/4"-20 Hex Nut– Qty. 8
(For –ST option – Qty. 12)
P . O . B o x 3 5 2 7
F a x : 6 2 6 . 9 6 1 . 2 2 0 0
1 of 12
0337-050-000
TRUE SIZE
0331-005-000
TRUE SIZE
TRUE SIZE
0302-005-000
TRUE SIZE
Rev. H – 03/07/05

Advertisement

loading
Need help?

Need help?

Do you have a question about the Meridian 3792 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Acorn Meridian 3792

  • Page 1 (For –ST option – Qty. 12) TRUE SIZE TRUE SIZE Acorn Engineering Company • 1 5 1 2 5 P r o c t o r A v e n u e P . O . B o x 3 5 2 7 C i t y o f I n d u s t r y •...
  • Page 2 Some available options may affect installation procedures. Please review the entire manual before proceeding. Corterra and stainless steel should be protected throughout installation to prevent damage to surface finish. Refer to the Care and Cleaning section of this manual. Rough-In Dimensions For Standard 34” Rim 3/8”...
  • Page 3 1. Disassemble access panels and deck assembly from frame. Anchor frame to wall using 3/8” mounting hardware by others. -See DETAIL A. Place deck assembly on frame, DETAIL A making sure angle engages behind frame joggle. -See DETAIL B. Assemble underside of bowls to frame with 1/4”-20 x 1/2”...
  • Page 4 3. Install grid strainers with plumbers putty. Assemble waste piping using Teflon tape and make-up connection. Before making up the supply connections, the supply lines must be flushed of all foreign material such as pipe dope, pipe chips, solder, sand, etc. VALVE RESTRICTIONS: Maximum Pressure 100 PSI.
  • Page 5 -H Hand Operation Valve Shown Upright For Reference Only Timing Screw. Ferrule Nut Turn timing screw to adjust metering. Do not overtighten ferrule nuts. Turn timing screw clockwise Ferrule Nut to increase timing. ¼” Min. Leave a minimum 1/4” of polyethylene tubing through the Ferrule Nut on the pushbutton assembly.
  • Page 6 -SO Sensor Operation Range Adjustment Make sure power supply is disconnected from sensor and make short circuit on Jumper DETAIL A By Others red wires. See DETAIL A. Connect power supply to sensor. Move hand in front of sensor to distance of 2”...
  • Page 7 -SO-BAT Sensor Operation – Battery Powered Valve Shown Upright For Reference Only Acorn does not provide batteries for –BAT units. Each station requires (6) AA batteries. To service or install batteries remove access panel by removing 10-32 x 3/4” screws from front of fixture using allen head bit provided (socket &...
  • Page 8 5. Install front and side access panels using 10-32 x 3/4” screws provided. DETAIL DETAIL D -DV Soap Option Soap Filler L1000802 Rev. H – 03/07/05 8 of 12...
  • Page 9 TROUBLE SHOOTING FOR HAND PUSHBUTTON OPERATED VALVES Normal Valve Function: Hand pushbutton operated valve has an adjustable flow time of 5 to 60 seconds. CONDITION: WATER DOES NOT FLOW Probable Cause: Solution: Water Main Closed. Open Water Main. Checkstops Closed. Open Checkstops.
  • Page 10 TROUBLE SHOOTING FOR 9 VOLT DC SENSOR OPERATED VALVES Normal Valve Function: 9 Volt DC sensor operated valve has flow time of 90 seconds maximum. To reactivate, the user must move out of and return to the sensing area. CONDITION: WATER DOES NOT FLOW Indicators: Probable Cause: Solution:...
  • Page 11: Repair Parts

    REPAIR PARTS Description Part No. Diagram #10-32 UNF Stainless Steel Nut Retainer 0316-018-000 SPOUTS Nozzle Assembly 6214-005-001 Spanner Key for Spout Aerator and Soap Filler 2998-055-199 -H SPOUTS Push Button Assembly 2566-050-001 -SO HARDWARE Sensor Assembly 2562-373-001 9 VDC Plug-In Transformer 0711-410-001 9 VDC Solenoid 2563-326-001...
  • Page 12: Warranty Information

    WARRANTY INFORMATION Acorn warrants that all of its products are guaranteed against defective material or poor workmanship for a period of one year from date of shipment. Acorn's liability under this warranty shall be discharged by replacing without charge F.O.B. City of...