Hood Installation

Note: All wiring installation must comply with local and national electrical code
regulations.
1. Lift the hood into position and guide the electrical cable through the electrical
cable clamp on the hood.
2. Insert the 4 wood screws from the bottom and securely fasten.
3. Secure the electrical cable in the cable clamp while allowing sufficient length in
the hood to connect the field wires to the hood wires.
4. Make the electrical connections using screw-on wire connectors. Attache the
black wires together and then the white wires together and then the green or
bare wire to the green grounding screw in the hood. Replace the wiring
compartment cover.
Caution! All wiring installation must comply with local and national electrical code
regulations.
5. Attach ductwork and use duct tape to seal all joints.
6. After turning all range hood switches to the OFF position, turn the power ON
and test your installation.