Wiring Diagrams

Installing Ductwork

• Your new range hood will operate at the highest efficiency if the number of elbow
and the length of the duct are kept to a minimum. The back draft damper flap
attached to the damper frame assembly, which is supplied with the hood, does not
impede airflow significantly. You may leave this in place even if you install a wall
or roof cap with another back draft damper.

Hood Installation

Note: All wiring installation must comply with local and national electrical code
regulations.
1. Transfer mounting holes to wall where hood is to be mounted.
2. Lift the hood into position and guide the electrical cable
through the electrical cable clamp on the hood.
3. Securely fasten the four wood screws.
4. Secure the electrical cable in the cable clamp while allowing sufficient length in
the hood to connect the field wires to the hood wires. Attach damper to the top
of the hood.