Technical Data; Operating Conditions - IMAGO VisionCam XM Hardware Manual

Hide thumbs Also See for VisionCam XM:
Table of Contents

Advertisement

3 Technical Data

3 Technical Data

Operating Conditions

Power Supply:
Parameter
Supply voltage
Supply voltage for use with internal ring light
1
Supply current
(@24V)
RS-232:
Parameter
RX signal input range
TX output voltage swing (R
Data rate, R
= 3kOhm, C
L
Digital Input:
Parameter
Input voltage range
Input current range (limited by internal circuit)
Threshold voltage
Threshold current
Input delay
Digital Output:
Parameter
Common VCC supply voltage (V
Output current, saturated operation: (V
Turn-On time (24 V common VCC, 10 mA)
Turn-Off time (24 V common VCC, 10 mA)
1
Actual current draw depends on hardware configuration and CPU/system load
Strassheimer Str. 45; 61169 Friedberg; Germany; Tel. +49(0)6031-6842611
= 3 kΩ)
L
= 1000 pF
L
- V
)
CC
OUT
- V
CC
OUT
IMAGO Technologies GmbH
info@imago-technologies.com;
Min
11
Min
– 25
 5
1200
Min.
0
0
6
Min.
) < 1 V
www.imago-technologies.com
Page 8 / 39
Typ.
Max
Unit
26.4
V
24
V
0.25
A
Typ.
Max
Unit
25
V
 5.4
V
115200
bps
Typ.
Max.
Unit
30
V
21
mA
11
V
1
5
mA
250
ns
Typ.
Max.
Unit
30
V
10
mA
5
µs
15
µs