SmartLogger3000
User Manual
Alarm
Alarm Name
ID
7.4 WebUI Maintenance Operations
7.4.1 Upgrading the Device Firmware Version
Context
You can upgrade the software of the SmartLogger, inverter, Smart PCS, Smart
String ESS, MBUS module, or PID module on the WebUI.
Procedure
Step 1 Perform an upgrade.
Figure 7-1 Upgrade
Issue 10 (2022-08-20)
Alarm
Alarm
Severity
Sub-ID
Minor
7
Minor
8
Copyright © Huawei Technologies Co., Ltd.
Cause
Suggestions
No available
1. Check whether the DC cable
PCS.
connection of the PCS is
normal.
2. Check whether the
connection box switch on the
DC side of the PCS is turned
on.
3. Check whether the
communication between the
PCS and the SmartLogger is
normal.
The black
Check the PCS device alarms and
start of the
handle them based on the alarm
PCS failed.
clearance suggestions.
7 Device Maintenance
242