Reliability Test; Test Conditions; Specifications - Toshiba LTD121EA43G Manual

Tft-lcd module without backlight
Table of Contents

Advertisement

6.6 Reliability Test (Reference)

6.6.1 Test Conditions

1) The module without backlight should be driven and inspected under normal test conditions.
2) The module without backlight should not have condensation of water (moisture) on the module without backlight.
3) The module without backlight should be inspected after two or more hours storage in normal conditions
(15 - 35°C, 45 - 65%(RH)).
4) A module without backlight shall be used only for one test.

6.6.2 Specifications

The module without backlight shall have no failure in the following reliability test items.
Test Item
High Temperature Operation
High Temperature Storage
High Temperature and
High Humidity operation
Low Temperature Operation
Low Temperature Storage
Temperature Shock
Note 1) Operating
Note 2) Non-Operating
 
Definitions of failure for judgment shall be as follows:
1) Function of the module without backlight should be maintained.
2) Current consumption should be smaller than the specified value.
3) Appearance and display quality should not have distinguished degradation.
Toshiba Matsushita Display Technology Co.,Ltd
Specification No.
3)
Test Conditions
1)
50°C
192 h
2)
60°C
192 h
50°C
80% 192 h
1)
1)
0°C
192 h
2)
-20°C
192 h
-20°C ⇔ 60°C
2)
0.5h
0.5h
50 cycles
Date: 2004-04-20
Date:
←# Special
Result
3p/3p OK
3p/3p OK
3p/3p OK
3p/3p OK
3p/3p OK
3p/3p OK
New No. LTD121EA43G-01
Old
No.
←& Addition
← Change
Sheet 31

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ltd121ea43g-01