The "X" after the certificate number refers to special conditions for safe use of the device, which have been listed in these instructions. If needed the EU type examination certificate can be downloaded from the manufacturer's website. 04/2021 - 4003591803 - AD OPTIBAR 5060 Exia R03 en www.krohne.com...
Assembly, installation, start-up and maintenance may only be performed by personnel trained in explosion protection! CAUTION! The operator or his agent is responsible for observing any additional standards, directives or laws if required due to operating conditions or place of installation. www.krohne.com 04/2021 - 4003591803 - AD OPTIBAR 5060 Exia R03 en...
Permissible process pressure 7 Electronics power supply and signal output 8 Ingress protection and material of wetted parts (Diaphragm, process connection, sealing and fill fluid) 9 Approvals and approval directive 04/2021 - 4003591803 - AD OPTIBAR 5060 Exia R03 en www.krohne.com...
Permissible process pressure 6 Electronics power supply and signal output 7 Ingress protection and material of wetted parts (Diaphragm, process connection, sealing and fill fluid) 8 Approvals and approval directive www.krohne.com 04/2021 - 4003591803 - AD OPTIBAR 5060 Exia R03 en...
2G. The sensor is installed in hazardous areas requiring instruments of category 1G. Category 2G equipment (EPL Gb equipment) The devices are installed in hazardous areas requiring equipment category 2G. 04/2021 - 4003591803 - AD OPTIBAR 5060 Exia R03 en www.krohne.com...
EPL, suitable for zone 0 Ga/Gb EPL, suitable for zone 0 / zone 1 EPL, suitable for zone 1 T6...T1 Temperature class, suitable for temperature classes T6...T1 Table 2-1: Protection types www.krohne.com 04/2021 - 4003591803 - AD OPTIBAR 5060 Exia R03 en...
The maximum permissible temperature of the electronics/housing should not exceed the values given in the table above. The application conditions in areas without hazardous mixtures are specified in the manufacturer information. 04/2021 - 4003591803 - AD OPTIBAR 5060 Exia R03 en www.krohne.com...
Page 10
The maximum permissible temperature of the electronics/housing should not exceed the values given in the tables above. The application conditions in areas without hazardous mixtures are specified in the manufacturer information. www.krohne.com 04/2021 - 4003591803 - AD OPTIBAR 5060 Exia R03 en...
1 Ambient temperature housing 2 Process temperature OPTIBAR PC 5060 (150°C / 302°F) Figure 2-4: Temperature derating - process temperature version (150°C / 302°F) 1 Ambient temperature housing 2 Process temperature 04/2021 - 4003591803 - AD OPTIBAR 5060 Exia R03 en www.krohne.com...
Page 12
6 Piezoresistive or strain gauge measuring cell, process temperature without cooling elements max. 105°C / 221°F 7 Piezoresistive or strain gauge measuring cell, process temperature with cooling elements max. 150°C / 302°F www.krohne.com 04/2021 - 4003591803 - AD OPTIBAR 5060 Exia R03 en...
Table 2-8: Electrical data for OPTIBAR * 5060 with integrated electronics Z, H or A, version with double chamber housing D, W or R 04/2021 - 4003591803 - AD OPTIBAR 5060 Exia R03 en www.krohne.com...
Page 14
Table 2-10: Intrinsically safe circuit for the display and adjustment module OPTIBAR * 5060 with integrated electronics Z, H or A, version with single chamber housing A, K, V or 8 www.krohne.com 04/2021 - 4003591803 - AD OPTIBAR 5060 Exia R03 en...
Page 15
For applications that require equipment category 1G or 1/2G, it is preferable to connect the OPTIBAR * 5060 VGK5/6/D*A/W/V C/U/0/H/T to appropriate equipment with galvanically isolated, intrinsically safe circuits. 04/2021 - 4003591803 - AD OPTIBAR 5060 Exia R03 en www.krohne.com...
= 0.62 H/m must be taken into account additionally. Table 2-12: Electrical data for OPTIBAR * 5060 with integrated electronics P or F, version with single chamber housing A, K, V or 8 www.krohne.com 04/2021 - 4003591803 - AD OPTIBAR 5060 Exia R03 en...
Page 17
= 0.62 H/m must be taken into account additionally. Table 2-13: Electrical data for OPTIBAR * 5060 with integrated electronics P or F, version with double chamber housing D, W or R 04/2021 - 4003591803 - AD OPTIBAR 5060 Exia R03 en www.krohne.com...
Page 18
Table 2-15: Intrinsically safe circuit for the display and adjustment module OPTIBAR * 5060 with integrated electronics P or F with single chamber housing A, K, V or 8 www.krohne.com 04/2021 - 4003591803 - AD OPTIBAR 5060 Exia R03 en...
Page 19
For applications that require equipment category 1G or 1/2G, it is preferable to connect the OPTIBAR * 5060 VGK5/6/D*A/W/V C/U/0/H/T to appropriate equipment with galvanically isolated, intrinsically safe circuits. 04/2021 - 4003591803 - AD OPTIBAR 5060 Exia R03 en www.krohne.com...
For applications that require equipment category 1G or 1/2G, it is preferable to connect the OPTIBAR * 5060 VGK5/6/D*A/W/V C/U/0/H/T to appropriate equipment with galvanically isolated, intrinsically safe circuits. www.krohne.com 04/2021 - 4003591803 - AD OPTIBAR 5060 Exia R03 en...
Only for connection to the display and adjustment module. electronics compartment) Table 2-18: Electrical data for OPTIBAR * 5060 with integrated electronics H or A and additional electronics Z 04/2021 - 4003591803 - AD OPTIBAR 5060 Exia R03 en www.krohne.com...
For applications that require equipment category 1G or 1/2G, it is preferable to connect the OPTIBAR * 5060 VGK5/6/D*A/W/V C/U/0/H/T to appropriate equipment with galvanically isolated, intrinsically safe circuits. www.krohne.com 04/2021 - 4003591803 - AD OPTIBAR 5060 Exia R03 en...
• they are not in a pneumatic flow. • excessive dust deposits (over 5 mm) and complete dust coverage are prevented. • there is no danger from mechanical impact effects. 04/2021 - 4003591803 - AD OPTIBAR 5060 Exia R03 en www.krohne.com...
4.5 Material resistance For applications requiring equipment category 1G or 1/2G, the OPTIBAR * 5060 VGK5/6/D*A/W/V C/U/0/H/T must only be used in products against which the wetted materials are sufficiently resistant. www.krohne.com 04/2021 - 4003591803 - AD OPTIBAR 5060 Exia R03 en...
With the version with remote housing of the pressure transmitter OPTIBAR * 5060 VGK5/6/D*A/W/V C/U/0/H/T the equipotential bonding must be provided in the complete mounting area of the connection cable between electronics housing and probe housing. 04/2021 - 4003591803 - AD OPTIBAR 5060 Exia R03 en www.krohne.com...
Page 27
NOTES OPTIBAR 5060 04/2021 - 4003591803 - AD OPTIBAR 5060 Exia R03 en www.krohne.com...
Page 28
Engineering, commissioning, calibration, maintenance and training services Head Office KROHNE Messtechnik GmbH Ludwig-Krohne-Str. 5 47058 Duisburg (Germany) Tel.: +49 203 301 0 Fax: +49 203 301 10389 info@krohne.de The current list of all KROHNE contacts and addresses can be found at: www.krohne.com...
Need help?
Do you have a question about the OPTIBAR 5060 eDP and is the answer not in the manual?
Questions and answers