Operation; Commissioning - Panduit CTFP-25 Original Operating Instructions

Benchmount pneumatic crimping press
Table of Contents

Advertisement

Available languages

Available languages

© Panduit Corp. 2019
3.

OPERATION

3.1

Commissioning

• Check whether finger guard (1) is present
and is sitting firm.
• Check whether the die set (2) is free from
foreign matter.
• Check whether the pneumatic tubing nuts
(3) have been tightened firmly.
• Insert the table clamp (4) into the bore hole
in the tabletop unit and screw tightly to the
worktable.
• Check the compressed-air supply:
min. 4 bar, max. 6 bar filtered air
Connect the free connection (5) on
the foot switch to the compressed-air
supply
3.2
Operation
Introduce stripped wire with wire-end
ferrules already fitted, at the side (1) or
from the front (2).
Press the switch (3), the crimping
process will be triggered.
Release the switch (4), the crimped wire
can be removed again (5).
PA29442A01_02_ENG
OPERATING INSTRUCTIONS
Figure 2 - Commissioning
Figure 3 - Operation
Page: 5 of 8
CTFP-25
ENGLISH
3-2019