Belt Replacement; Bulb Replacement; Motor Replacement - Panasonic MC-UG471-00 Service Manual

Table of Contents

Advertisement

MC-UG471-00
housing.
5. Press firmly, checking to see that each end is completely
inserted.
6. Check to see that the belt is centered in the belt groove.
7. Rotate the agitator assembly by hand to insure nothing
rubs and check for correct assembly.
8. Replace the lower plate as outlined in the LOWER PLATE
REMOVAL/INSTALLATION section.
3.3.

Belt Replacement

3.3.1.
Removal
1. Remove the lower plate as outlined in LOWER PLATE
REMOVAL/INSTALLATION section.
2. Remove the agitator assembly as outlined in the
AGITATOR ASSEMBLY section.
3. Remove old belt.
3.3.2.
Installation
1. Place the new belt around the motor shaft.
2. Install the agitator assembly as outlined in the AGITATOR
ASSEMBLY section.
3. Install the lower plate as outline in LOWER PLATE
REMOVAL/INSTALLATION section.
3.4.

Bulb Replacement

3.4.1.
Removal
1. Ensure ON-OFF switch is OFF and disconnect power cord
from electrical outlet.
2. Press handle release pedal and rotate the handle down so
the vacuum cleaner is laying flat on the floor.
3. Pry out light lens at slots. Remove old bulb from the socket
by pulling from socket.
3.4.2.
Installation
1. Replace bulb by pressing into socket. Only use a bulb rated
13 V AC-9 Watts.
2. Reinstall light lens by snapping into place.
3. Return the vacuum cleaner to the upright position.
3.5.

Motor Replacement

3.5.1.
Removal
1. Pull outward on the cover grip, located near the top of the
dust cover and remove the cover.
2. Grasp the dust bag collar and pull gently, carefully removing
the dust bag.