TROUBLESHOOTING AND FAQ

ERROR CODE

If these error codes appear on the display, here you can find a list of solutions
to try to resolve the problem yourself.
The thermal ventilation unit must be on only when it is correctly inserted into
the drying tunnel. Ensure that it is paused (fan off) when it is removed from
its position.
ERROR CODE
assistenza@tauroessiccatori.com
How much does my BIOSEC consume?
The BIOSEC motor has been designed specially to optimise consumption
under all circumstances and even includes a dedicated program for ener-
gy saving. As specified on the technical datasheet, the BIOSEC motor con-
sumes up to a maximum of 550W. This means that the consumption indi-
cated occurs only when the motor is heating up to the highest limits (e.g. 68°
on program P4) and the fan reaches maximum speed. At all other times, the
BIOSEC consumes on average amounts that vary between approximately
15W and 350W, depending on the program selected and the stage of the
program that is in progress.
40
PROBLEM
PROBLEM WITH
ELECTRICAL CONNECTION
PROCESS TEMPERATURE
DETECTED IS TOO HIGH
TEMPERATURE SAFETY
THRESHOLD EXCEEDED
PROBLEM WITH
ELECTRICAL CONNECTION
www.tauroessiccatori.com
SOLUTION
Contact support.
Check that the fan is rotating
and the air flow is not obstructed.
Enter program T1 to cool the machine
down.
Check that the fan is rotating
and the air flow is not obstructed.
Turn of and on again.
Contact support.
+39 0444 719046
-