7.3.39.2 MC-12 Unit Configuration Response Packet
Application Header:
Command MC_RESP_UNIT_CONFIG
Data Count 30
Application Data:
Data[0]
Data[1]
Data[2]
Data[3]
Data[4]
Data[5]
Data[6]
Data[7]
Data[8]
Data[9]
Data[10]
Data[11]
Data[12]
Data[13]
Data[14]
Data[15]
Data[16]
Data[17]
Data[18]
Data[19]
Data[20]
Data[21]
Data[22]
Data[23]
Data[24]
Data[25]
Data[26]
Data[27]
Data[28]
Data[29]
7.3.39.3 Data Description
ProductId:
This unsigned 8 bit value describes the product.
Software Type:
An unsigned 8 bit value indicating the current configuration of the unit's
software. The following table shows the values assigned to the available types:
© 2005 Harman Specialty Group All rights reserved.
ProductId
Software Type
Software Level
Software Major Revision
Software Minor Revision
Protocol Major Revision
Protocol Minor Revision
Parameter Count Low(LSB)
Parameter Count High(MSB)
Effect Count
TimeStamp[0]
TimeStamp[1]
TimeStamp[2]
TimeStamp[3]
TimeStamp[4]
TimeStamp[5]
TimeStamp[6]
TimeStamp[7]
TimeStamp[8]
TimeStamp[9]
TimeStamp[10]
TimeStamp[11]
TimeStamp[12]
TimeStamp[13]
TimeStamp[14]
TimeStamp[15]
SerialNumber(LSB)
SerialNumber
SerialNumber
SerialNumber(MSB)
Product ID
Lexicon DC-2
Lexicon MC-1
JBL Synthesis SDP-3
Lexicon MC-12
JBL Synthesis SDP-40
Printed on: 07/13/05
0x91
0x1E
nn
nn
nn
nn
nn
nn
nn
nn
nn
nn
ch
ch
ch
ch
ch
ch
ch
ch
ch
ch
ch
ch
ch
ch
ch
0x00
nn
nn
nn
nn
1
2
3
4
5