Class Unit In Single Operation - Mitsubishi Electric MXZ-2C20NA2 Service Manual

Outdoor unit
Hide thumbs Also See for MXZ-2C20NA2:
Table of Contents

Advertisement

5. 06-class unit in single operation (OUTDOOR UNIT: MXZ-3C24NA MXZ-3C24NA2 MXZ-3C24NA3 MXZ-3C24NA4
(1) COOL operation
Data is based on the condition of indoor humidity
50%
Air flow speed: High
Inverter output frequency: 24 Hz
(PSIG)
160
150
140
130
120
110
65 70 75 80 85 90 95 100 105 110 115
Ambient temperature (˚F)
(2) HEAT operation
Data is based on the condition of outdoor humidity
75%.
Set air flow to High speed.
Inverter output frequency is 32 Hz.
OBH702N
MXZ-3C30NA MXZ-3C30NA2 MXZ-3C30NA3 MXZ-3C30NA4
MXZ-4C36NA MXZ-4C36NA2 MXZ-4C36NA3 MXZ-4C36NA4)
<How to work fixed-frequency operation>
1. Set emergency switch to COOL or HEAT. The switch is located
on indoor unit.
2. Press emergency run ON/OFF button.
3. Compressor starts running at 24 Hz (COOL) or 32 Hz (HEAT).
4. Indoor fan runs at High speed and continues for 30 minutes.
5. To cancel this operation, press emergency run ON/OFF button
or any button on remote controller.
6.0
86
5.0
80
4.0
75
3.0
2.0
70
24 Hz
1.0
0.0
(˚F)
65 70 75 80 85 90 95 100 105 110 115
7.0
6.0
5.0
4.0
3.0
2.0
15 20 25 30 35 40 45 50 55 60 65 70 75
94
24 Hz
Ambient temperature (˚F)
32 Hz
Ambient temperature (˚F)
86
80
75
70
(˚F)
75
70
65
(˚F)