Mitsubishi Electric MXZ-2C20NA2 Service Manual page 66

Outdoor unit
Hide thumbs Also See for MXZ-2C20NA2:
Table of Contents

Advertisement

MXZ-4C36NA MXZ-4C36NA2 MXZ-4C36NA3
R.V.coil
OFF
Refrigerant flow in heating
ON
Refrigerant flow in cooling
Union
Header(Gas)
ø 1/2
Indoor unit A
ø 3/8
Indoor unit B
ø 3/8
Indoor unit C
ø 3/8
Indoor unit D
Union
Strainer
ø 1/4
#100
Indoor unit A
Strainer
ø 1/4
#100
Indoor unit B
Strainer
ø 1/4
#100
Indoor unit C
Strainer
ø 1/4
#100
Indoor unit D
MXZ-4C36NA4
R.V.coil
OFF
Refrigerant flow in heating
ON
Refrigerant flow in cooling
Union
ø 1/2
Indoor unit A
ø 3/8
Indoor unit B
ø 3/8
Indoor unit C
ø 3/8
Indoor unit D
Union
Strainer
ø 1/4
#100
Indoor unit A
Strainer
ø 1/4
#100
Indoor unit B
Strainer
ø 1/4
#100
Indoor unit C
Strainer
ø 1/4
#100
Indoor unit D
OBH702N
Compressor
High pressure switch
Muffler
Service port
Stop valve
(with service port)
Sub
muffler
Capillary tube
O.D.0.16 x I.D.0.11 x 3.94
(ø4.0 x ø2.8 x 100)
LEV A
LEV B
LEV C
Stop valve
LEV D
Compressor
High pressure switch
Muffler
Service port
Header(Gas)
Stop valve
(with service port)
Sub
muffler
Capillary tube
O.D.0.16 x I.D.0.11 x 3.94
(ø4.0 x ø2.8 x 100)
LEV A
LEV B
LEV C
Stop valve
LEV D
Accumulator
Compressor shell
temperature
thermistor
RT62
4-way valve
Capillary tube
Strainer
#100
Accumulator
Compressor shell
temperature
thermistor
RT62
4-way valve
Capillary tube
Strainer
#100
66
Service port
Header (Evaporator)
Outdoor
heat exchanger
Outdoor
heat exchanger
temperature
thermistor
RT68
Defrost
temperature
thermistor
RT61
Strainer
Distributor
#50
Service port
Header (Evaporator)
Outdoor
heat exchanger
Outdoor
heat exchanger
temperature
thermistor
RT68
Defrost
temperature
thermistor
RT61
Strainer
Distributor
#50
Unit: inch (mm)
Ambient
temperature
thermistor
RT65
Ambient
temperature
thermistor
RT65

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents