Page 1
EPILOG LASER 16371 Table Mountain Parkway Golden, Colorado 80403 Phone 303-215-9171 - FAX 303-277-9669 www.epiloglaser.com Procedure Title: Replacing the Z-motor Machine Type: FiberMark Tools Needed: #1 Philips head screw driver 5/16 Nut Driver 3/32 Hex wrench Wire Cutters Pencil Intro: This procedure details steps to replacing the Z-motor.
Page 2
4. There are two white connectors on the wires that come from the z-motor and connect to the main harness. The connectors are shown in picture 2. Disconnect both connectors from the main harness. Picture 2 5. There are three Philips head screws (identified by the circles) which secure the motor assembly to the machine chassis.
Page 3
7. We now have to remove the bracket and pulley from the motor to get the motor completely out of the assembly. 8. To remove the pulley you will need to loosen the set screw with an 3/32 Hex wrench. See picture 4 below to see where the set screw is located. Picture 4 9.
Page 4
13. Loosely install the three Philips screws. 14. Line the motor mount up with the marks that you made before the mounting screws were removed and tighten the mounting screws. 15. Reconnect the two white motor connectors to the main harness. 16.