Specifications

Model: 570DMM or 570DMD Elite Flow Through Humidifiers (GFI #5710 & #5705)
Type: Flow Through
GPD: 12 Based on 120° F / 49° C Plenum Temperature
Warranty (Years): 10
Replacement Vapor Pad®: GA10 (GFI#7900) (Replace 1-2 times per season)
Dimensions (Inches): 11-7/8 W x 13-3/8 H x 9-1/2 D
Weight (Pounds): 7
Home Size (Square Feet): To 2,000
Installation: Warm Air / Return Air Plenum / Right or Left Side
Plenum Opening (Inches): 8-7/8 W x 9-1/2 H
Bypass Opening (Inches): 6
Pallet Qty: 36
Cabinet Construction: UV-Stable Automotive Grade Plastic
Humidistat (Included): "M" Models: MHX3C / "A" Models: GFX3
Voltage: 24VAC
In The Box: Humidifier, Humidistat, Control Bypass Damper, 24V Transformer, Solenoid Valve, Vapor Pad
Saddle Valve, (GCV3412 Code Valve - A Models), Installation Instructions, Template, Parts.
Expected Humidity Performance Coverage in Square Feet Based on Construction Type
Model No.
Elite 570
Elite 900
Elite 1000
Humidifier Performance Baseline Criteria
Outside Design Temperature
Outside Design R.H.
Inside Design Temperature
Inside Design R.H.
Air Changes/hour (AC/H)
Ceiling Height (Feet)
Furnace Plenum Temperature
Furnace Run Time For Calculating Sq. Ft.

Unit Location

• WARNING: Disconnect electrical power before beginning installation.
!
• Do not install where temperatures fall below 32°F / 0° C or where plenum temperatures exceed 200° F / 93° C.
For maximum evaporative capacity, install this humidifier on the warm air supply plenum.

Additional Materials That May Be Necessary:

1. 1/4" Diameter plastic supply tubing for cold water applications, or 1/4" copper supply tubing for hot water
applications
2. 6" Diameter galvanized by-pass pipe
3. Electrical wire and wire nuts
4. Current sensing relay (Model #GA50 - GFI #7026)
5. #8 Self-piercing sheet metal screws
Loose
GPD
(0.75 AC/H)
12
800 Sq. Ft.
17
1115 Sq. Ft.
18
1175 Sq. Ft.
0° F / -18° C
70% R.H.
70° F / 21° C
30% R.H.
0.30
8
120° F / 49° C
8 Hour /1 Day
Average
(0.50 AC/H)
1200 Sq. Ft.
1650 Sq. Ft.
1770 Sq. Ft.
Installation Options:
Warm Air Plenum
Return Air Plenum
Right or Left Bypass
Vertical or Horizontal
Furnace or Air Handler
Model 570 Humidifier Installation Manual
,
®
Tight
(0.30 AC/H)
2000 Sq. Ft.
2800 Sq. Ft.
3000 Sq. Ft.
www.generalfilters.com
3