Please Read And Save These Instructions
• Installation by anyone other than a qualified contractor voids the warranty.
• Product designed for residential installation only. Commercial installation voids warranty.
• Modification or alteration of product, parts, installation instructions or local safety codes voids warranty.
General Filters, Inc.
43800 Grand River Avenue
Novi, Michigan 48375
Toll Free: (866) 476-5101
www.generalaire.com
• Read our full warranty policy at the end of this document.
Canadian General Filters, Ltd.
400 Midwest Rd.
Toronto, ON M1P3A9 Canada
Toll Free: (888) 216-9184
www.cgfproducts.com
Breathe Healthier
Humidifier
GFI #5710 & 5705

Advertisement

Table of Contents
loading

Summary of Contents for GeneralAire 570DMM

  • Page 1 • Installation by anyone other than a qualified contractor voids the warranty. • Product designed for residential installation only. Commercial installation voids warranty. • Modification or alteration of product, parts, installation instructions or local safety codes voids warranty. • Read our full warranty policy at the end of this document. Breathe Healthier General Filters, Inc. Canadian General Filters, Ltd. 43800 Grand River Avenue 400 Midwest Rd. Novi, Michigan 48375 Toronto, ON M1P3A9 Canada Toll Free: (866) 476-5101 Toll Free: (888) 216-9184 www.generalaire.com www.cgfproducts.com...
  • Page 2: Table Of Contents

    Model 570 Humidifier Installation Manual Model 570 Table of Contents Table of Contents Specifications Unit Location Additional Materials That May Be Necessary: Installation Installing / Wiring The Control How The Humidifier Works Maintenance Parts Drawing Inside Your Box Humidifier Chassis Cut Out Trouble Shooting FAQ’s Limited Warranty...
  • Page 3: Specifications

    Model 570 Humidifier Installation Manual Specifications • Model: 570DMM or 570DMD Elite Flow Through Humidifiers (GFI #5710 & #5705) • Type: Flow Through • GPD: 12 Based on 120° F / 49° C Plenum Temperature • Warranty (Years): 10 •...
  • Page 4: Installation

    Model 570 Humidifier Installation Manual Installation 1. The Model 570 may be installed on either the supply or return plenum of a forced air handling system. Select a location for the humidifier that allows for service and maintenance. Cut out a rectangle 8-7/8” wide by 9 1/2“ tall. Extend horizontal centerline of cut out to the adjacent plenum.
  • Page 5 Model 570 Humidifier Installation Manual Installation Cont. Mount the self tapping saddle valve or code valve on either a cold or a hot water pipe. A side or top mount is best to Brass Sleeve avoid clogging from pipe sediment. Connect 1/4” O.D. COPPER TUBING tubing to the saddle valve.
  • Page 6: Installing / Wiring The Control

    Model 570 Humidifier Installation Manual Installing / Wiring The Control GFX3 (Automatic Models) MHX3 (Manual Models) OUTDOOR TEMP. SENSOR (NOT USED IN MANUAL MODE) HUMIDIFIER CONTROL LEADS (YELLOW WIRES) 24V OUTPUT FROM HUMIDIFIER (RED WIRES) OR 727-58 24 V. TRANSFORMER WITH CONSTANT POWER OR 24 VAC POWER SUPPLY WITH CONSTANT POWER Thin Gasket Thick Gasket...
  • Page 7: How The Humidifier Works

    Model 570 Humidifier Installation Manual How The Humidifier Works • The operating principle of the humidifier is based on the most efficient and economical means of evaporating water to the air. The humidifier uses only 2.5 watts of electrical power during operation; the heat necessary for evaporating water is produced by the furnace.
  • Page 8: Parts Drawing

    Humidifier components: GA10 Vapor pad, GA4040 Solenoid Assembly, Integral Bypass Damper Accessories: GFX3 Automatic Digital Humidistat, 24V Transformer, Code Valve, Saddle Valve Model 570DMM (GFI#5705) includes: Humidifier Components: GA10 Vapor Pad, GA4040 Solenoid Assembly, Integral Bypass Damper Accessories: MHX3 Manual Humidistat, 24V Transformer, Saddle Valve...
  • Page 9: Humidifier Chassis Cut Out

    • Verify water supply is on. • Check for voltage at the solenoid valve. Voltage should be 24VAC. • Verify wiring of humidifier and humidistat. • Contact licensed GeneralAire contractor to verify voltage in and out of the relay board, and replace if necessary. ®...
  • Page 10: Faq's

    5. Dry air can cause harm to expensive musical instruments like pianos and violins. 6. Dry air causes gaps in window & door frames, letting cold outdoor air in; causing you to turn up the heat and increasing your heating bills! Controlled humidity from the GeneralAire Elite Steam Humidifier allows ®...
  • Page 11: Limited Warranty

    Model 570 Humidifier Installation Manual Limited Warranty What is Covered • Ten Years: The 570 Humidifier is warranted by General Filters, Inc. (“Company”) for a period of ten (10) years from the date of the original installation, when installed in residential applications only (“Limited Warranty Period”). •...
  • Page 12 Model 900 Humidifier Installation Manual Limited Warranty, Cont. Limitations Of Liability • General Filters, Inc. makes no express warranties other than the warranty specified above. • The implied warranties of merchantability and fitness for a particular purpose are limited to the duration listed. •...
  • Page 13 LIRE ET ENREGISTRER CES INSTRUCTIONS SÉRIE 570 INSTALLATEUR : VEUILLEZ REMPLIR ET POSTER LA CARTE DE GARANTIE UNE FOIS L’INSTALLATION TERMINÉE. LAISSER LES DIRECTIVES HUMIDIFICATEUR À D’INSTALLATION AU PROPRIÉTAIRE DE LA MAISON. CIRCULATION DIRECTE POUR UNE INSTALLATION SUR LA PRÉCAUTION : L’installateur doit être un technicien qualifié et expérimenté. Couper l’alimentation électrique SURFACE VERTICALE DU PLÉNUM avant de commencer l’installation.
  • Page 14 INSTRUCTIONS D’INSTALLATION DE LA VANNE-CODE GCV3412 Tuyau en cuivre 1. Couper l’alimentation en eau. 2. Nettoyer le tuyau, les raccords et la vanne avec du papier abrasif ou une brosse métallique. 3. Appliquer une fine couche de flux sur toutes les surfaces devant être soudées.
  • Page 15 LISTE DES PIÈCES POUR L’HUMIDIFICATEUR 570-40 RAIL DU TAMPON 570-1 CADRE 900-9 GICLEUR GA-10 TAMPON D’ÉVAPORATION 900-10 BUSE GA4226 TUBE DE COMPRESSION 900-15 GOULOTTE DU DISTRIBUTEUR 900-11 BOUTON DU REGISTRE 900-28 DISQUE DU REGISTRE 570-2 ÉVACUATION PANNEAU LATÉRAL 900-71 INSIGNE 570-13 COUVERCLE 900-14 BAC DE RÉCUPÉRATION GA4231 ORIFICE JAUNE...
  • Page 16 CARACTÉRISTIQUES DE L’HUMIDIFICATEUR ELITE 570 Performance d’humidité prévue selon la superficie en mètres carrés/pieds carrés et le type de construction Nº de modèle Moyen (0,50 CAH) Élevé (0,30 CAH) Faible (0,75 CAH) 186 m /2000 pi Elite 570 74 m /800 pi 111 m /1200 pi...