Drive Mounting - Seagate FIRECUDA ST2000DX002 Product Manual

Table of Contents

Advertisement

3.4 Drive mounting

Users can mount the drive in any orientation using four screws in the side-mounting holes or four screws in the bottom-
mounting holes. Refer to
precautions when mounting the drive:
• Allow a minimum clearance of 0.030 inches (0.76mm) around the entire perimeter of the drive for cooling.
• Use only 6-32 UNC mounting screws.
• The screws should be inserted no more than 0.120 inch (3.05mm) into the bottom or side mounting holes.
• Do not overtighten the mounting screws (maximum torque: 6 inch-lb).
Figure 2 Mounting dimensions (2TB model)
1.028 in max
26.11 mm
3X .250 ± .010 in
6.25 ± .25 mm
BOTH SIDES
2X 1.750 ± .010 in
Seagate FireCuda Product Manual, Rev. A
and
for drive mounting dimensions. Follow these important mounting
Figure 2
Figure 3
5.787 in max
146.99 mm
4.000 ± .010 in
101.60 ± .25 mm
1.638 ± .010 in
41.61 ± .25 mm
44.45 ± .25 mm
1.090 ± .050 in
27.69 ± 1.27 mm
0.640 ± .050 in
16.26 ± 1.27 mm
TOP OF LABEL
TEMPERATURE
CHECK POINT
5
1.122 ± .020 in
30.99 ± 0.51 mm
3X 6-32 UNC-2B
3 MINIMUM THREAD DEPTH
0.12 MAXIMUM FASTENER
PENETRATION BOTH SIDES
2X 1.625 ± .020 in
41.28 ± .51 mm
2X 0.130 in
3.30 mm
4X 6-32 UNC-2B
3 MINIMUM THREAD DEPTH
0.12 MAXIMUM FASTENER
PENETRATION
2X 3.740 in
95.00 mm
C L OF DRIVE
0.814 in
20.68 mm
C L OF CONNECTOR
DATUM B
0.140 in
3.56 mm
20

Advertisement

Table of Contents
loading

This manual is also suitable for:

Firecuda st1000dx002

Table of Contents