Type Designation Key - ABB PVS800-IS Hardware Manual

Table of Contents

Advertisement

Type designation key

The type designation describes the composition of the inverter station. The type designation
is visible on the type designation label which is attached to the inverter station. The complete
type designation is divided into sub codes:
The first 1...18 digits form the basic code which describes the basic construction of the
inverter station. The fields in the basic code are separated by hyphens.
The option codes follow the basic code. Each option code starts with an identifying letter
(common for the whole product series), followed by descriptive digits. The option codes
are separated by plus signs.
The following table describes the fields of the basic code.
Digit no.
Description
1...6
PVS800 product series
7...9
Construction. -IS = Inverter station
Steel frame container built, IP54 inverter compartment, C4 corrosion class, double-staged air filtering,
G4 filter class.
2 x PVS800-57B central inverters +G300 cabinet heater, +20H382, 20x fuse protected DC input
connections, optionally +24H382, 24x fuse protected DC inputs.
10...16
Nominal AC power.
-xxxxkW
See chapter
17...18
Nominal AC voltage
-C = 380 VAC
-C = 400 VAC
The following table describes the option codes.
Code
Description
Container options
G312
Upgrade to corrosion class C5 and filtering class F7. Required for near coastal installation locations
(site located more than 1 km and up to 10 km distance from medium to high saline coastal line).
G344
6 kVA auxiliary power transformer supplied from main AC side of an inverter (external auxiliary
power supply connection is not needed)
Container specialities
P902
Customized (see the project-specific documentation)
Technical data (page
53).
Hardware description 19