Switch
3192 Shelf Connections
The unit occupies two slots in a CI Wescom 3192
Office Repeater Bay. The unit may be plugged into
any of the first 28 slots of the shelf. No installation
wiring is required.
Power and alarm signals are provided to the card
through the backplane of the shelf. DSX-1 and HDSL
Loop signals are connected to the wire-wrap pins or
mass termination shelf connectors corresponding to
the slot the unit occupies. Connections to the DSX
pins are intended for intra-building wiring only. The
card edge pinout is shown in Figure 4.
The HTU-C contains an onboard fuse. If this fuse
opens, it supplies a -48 VDC to the fuse alarm bus; all
faceplate indicators will turn off. The fuse is not field
replaceable.
HDSL Loops 1 and 2 are
dual duplex loops (capable
of transmitting and receiving
data simultaneously).

Figure 4. Card Edge Connections

61179512L2-5A
Central Office
2-Wire
HD-10 BRI Mux
HD-10 BRI Mux
HD-10 BRI Mux
HD-10 BRI Mux
HD-10 BRI Mux
1181200L1
1181200L1
1181200L1
1181200L1
1181200L1
QFC-C
QFC-C
QFC-C
QFC-C
T1-OR
T1-OR
T1-OR
T1-OR
FXO
FXO
FXO
FXO
FXO
FXO
FXO
FXO
FXO
FXO
FXO
POWER
POWER
PWR
1181300L1
PWR
1181300L1
PWR
1181300L1
PWR
1181300L1
PWR
1181310L1
PWR
1181310L1
PWR
1181310L1
PWR
1181310L1
1181101L1
1181101L1
1181101L1
1181101L1
1181101L1
1181101L1
1181101L1
1181101L1
1181101L1
1181101L1
1181101L1
1181101L1
FXO
FXO
1181101L1
DSX
DSX
DSX
#1
DSX
#1
DSX
#1
DSX
#1
DSX
DSX
DSX
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
PWR
LBK
LBK
DSX
#2
DSX
#2
DSX
#2
DSX
LBK
LBK
DSX
DSX
DSX
DSX
DSX
DSX
DSX
DSX
DSX
DSX
DSX
DSX
DSX
DSX
DSX
#3
DSX
#3
DSX
#2
LP
LBK
LBK
TST
TST
TST
TST
TST
TST
TST
TST
TST
TST
TST
TST
TST
LBK
DSX
#4
DSX
#3
DSX
#3
LP
LP
LP
LP1
LP1
LP1
LP1
LP1
LP1
LP1
LP1
LP1
LP1
LP1
LP1
LP1
TST
#4
DSX
#4
DSX
#4
ALM
ALM
ALM
ALM
TST
TST
TST
+
+
+
+
X
T
X
R
X
T
R
X
X
T
R
X
X
T
R
X
Total Access1500 with FXO
Module

Figure 3. Universal DLC Configuration

1
R TX DSX (In from DSX)
2
R1 RX DSX (Out to DSX)
3
4
5
GND
6
R1 HDSL Loop 2
7
8
-48V
R HDSL Loop 1
9
Fuse Alarm (to Alarm Module)
10
A
T TX DSX (In from DSX)
B
T1 RX DSX (Out to DSX)
C
D
E
F
T1 HDSL Loop 2
H
RCV LOS (to Alarm Module)
Frame Ground
J
T HDSL Loop 1
K
L
Section 61179512L2-5, Issue 1
TRD DB
12910 04
T1
HDSL
ON
SC
64
NO
56
SX
19.2
9.6
SYNC
4.8
2.4
QM
CRC
FXO
1181101L1
LLB
PWR
QM
DSX
DISC
TST
AP
LP1
REM
NO
DSU
RX
(OUT)
LBK
TX
(IN)
CUSTOM
TELECO M
E190349
ICOT Module
Powering Options
The ICOT will power the entire Total Access 1000 RT
System. When an HRE is used to extend the range of
the circuit, a second ICOT provides span power to the
HRE through two additional copper pairs. The Total
Access 1000 RT continues to receive span power
through the HDSL loops.
Compliance
This product is intended for use in Restricted Access
Areas Only and is to be installed in a Type "B" or "E"
enclosure. Also, ensure chassis ground is properly
connected. Table 1 list the compliance codes.
LED Indicators
Table 2 describes the functionality of each of the six
faceplate LEDs.

3. PROVISIONING

Table 1. Compliance Codes

Code
Power Code (PC)
Telecommunication Code (TC)
Installation Code (IC)
The ICOT has no external provisioning switches. All
provisioning options are accessible via the VT100
terminal screens.
The DB-9 connector on the faceplate of the 3192
must be used to access the terminal screens. The
menu system enables provisioning, test access, and
alarm status monitoring of both the 3192 ICOT and
the modules in the Total Access 1000 RT. Also
through the menus, the ICOT and the Total Access
1000 BCU can be flash upgraded.
Customer Premises
POTS
POTS
POTS
POTS
POTS
POTS
1179408L1
BCU
BCU
1175012L1
1179408L1
1179408L1
1179408L1
1179408L1
1179408L1
BUSY
BUSY
PSU
1179007L1
1175012L1
BUSY
BUSY
BUSY
1
BUSY
1
1
LOOP 1
TEST
1
1
2
1
2
2
2
POWER
ALARM
2
2
3
3
3
3
3
LOOP 2
3
4
4
4
4
4
RG ON
4
RG DIS
A
M
D
N
I
Phone
Total Access 1000 RT
System
Input
F
A
Output
C
X
3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 3192 Integrated Central Office Terminal and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Ta1000 icot1179512l2

Table of Contents