Diagnostic Error Code
018-198-XXX
PCI Card test aborted
018-199-XXX
PCI Card test failed, cause unknown
018-250-XXX
PCI Card Services error
020-000-XXX
PCI Interface Test Passed
020-0XX-XXX
PCI Interface error
020-195-XXX
PCI Test aborted by user
020-196-XXX
PCI test halt, error threshold exceeded
020-197-XXX
PCI test warning
020-198-XXX
PCI test aborted
FRU/Action
1. If a component is called out, make sure it
is connected and/or enabled. See
Chapter 6, "Using the Setup Utility," on
page 49
2. Flash the system and re-test. See
"Updating (flashing) the BIOS from a
disc" on page 180
3. Go to "Undetermined problems" on page
80
1. Go to "Undetermined problems" on page
80
2. Flash the system and re-test. See
"Updating (flashing) the BIOS from a
disc" on page 180
3. Replace component under function test
1. PCI card
2. Riser card, if installed
3. System board
No action
1. PCI card
2. Riser card, if installed
3. System board
Information only
Re-start the test, if necessary
1. Press F3 to review the log file
2. Re-start the test to reset the log file
1. If a component is called out, make sure it
is connected and/or enabled. See
Chapter 6, "Using the Setup Utility," on
page 49
2. Re-run test
3. Replace the component that is called out
in warning statement
4. Replace the component under test
1. If a component is called out, make sure it
is connected and/or enabled. See
Chapter 6, "Using the Setup Utility," on
page 49
2. Flash the system and re-test. See
"Updating (flashing) the BIOS from a
disc" on page 180
3. Go to "Undetermined problems" on page
80