Association Group:
Thermostat supports 1 association group (0x01), which can include five Node ID. A
gateway is suggested to associate with this group. Then if any changes happen, such as:
temperature, working mode, fan state etc., the thermostat will report to this associated device
(gateway). All the reports sent via Lifeline group.
Commands sent via Lifeline:
COMMAND_CLASS_THERMOSTAT_MODE,
COMMAND_CLASS_THERMOSTAT_SETPOINT,
COMMAND_CLASS_THERMOSTAT_FAN_MODE,
COMMAND_CLASS_SENSOR_MULTILEVEL,
COMMAND_CLASS_CONFIGURATION,
COMMAND_CLASS_DEVICE_RESET_LOCALLY
Configuration CC:
Parameter
Parameter Name
Number/Size
4/2
5/2
Heating method
6/2
Master and slave
9/2
10/2
Algorithm enable
17/2
20/2
temperature limit
21/2
temperature limit
25/2
82/2
84/2
Weather theme
Z-WAVE SPECIFICATION
Parameter Values Description
Custom mode
2-Fan coil and floor heating both
setting
Summer
Value range: -50~50(-50 means
temperature
difference
calibration
Calibration for the temp. sensor
Theme style
0-classic/1-weather/2-Digital
clock/3-Rome clock/4- cartoon
Lower
Value range:50~350(50 means
Upper
Value range:50~350(50 means
Winter
Value range:-50~50(-50 means
temperature
difference
Calibration for the temp. sensor
calibration
Outdoor
temperature
0-standard mode
2-Sleeping night mode
3-Sleeping noon mode
0-Heating by fan coil only
1-Floor heating only
0-Slave
1-Master
△T=-5℃)
Precision:1
in summer
0-off 1-on (have no use
currently)
clock
for 5℃, 350 means
35℃)Precision:1
for 5℃, 350 means
35℃)Precision:1
△T=-50℃)Precision:1
in winter
Value range: -50℃~50℃
Precision:0
0-sunny
1-windy
10
Default value
0
0
0
0
0
0
50
350
0
0