Haier HBU-18HF03 Manual page 241

Single split r22
Table of Contents

Advertisement

For
Failure
For
remote
code
on
control,
type, flash
wired
failure code
times
controller
10
08
21
1
01
01
2
02
02
3
4A
11
4
49
12
5
48
10
6
53
14
8
07
06
9
06
05
11
0B
30
12
03
20
13
0D
31
15
05
17
16
54
26D
central
Failure description
Drainage system failure
Indoor ambient temp. sensor
failure
Indoor coil temp. sensor failure
Outdoor ambient temp. sensor
failure
Outdoor
coil
temp.
failure
discharging temp. sensor)
Over-current protection
High pressure abnormal
Communication between wired
controller and indoor abnormal
Communication
indoor and outdoor abnormal
Outside alarm signal input
Gas
pipe
temp.
abnormal
Solenoid valve abnormal
EEPROM abnormal
Outdoor pressure switch or
discharging protector abnormal
-241-
Reason
Float switch broken down for more than
25m continuously
sensor broken down or short circuit for
more than 2m continuously
sensor broken down or short circuit for
more than 2m continuously
sensor broken down or short circuit for
more than 2m continuously
sensor
Sensor broken down or short circuit for
(compressor
more than 2m continuously
CT check abnormal 3 times in 30m
High pressure switch acts 3 times in 30m
Communication abnormal for more than
4m continuously
between
Communication abnormal for more than
4m continuously
Outside signal broken down for more than
10s
sensor
Sensor broken down or short circuit for
more than 2m continuously
Solenoid valve act incorrectly 3 times
continuously
EEPROM data missing
Pressure switch or discharging protector
disconnected; or CN11 on indoor PCB
disconnected. The failure occurs only
when there is no outdoor PCB.
Failure code

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents