Haier HBU-18HF03 Manual page 218

Single split r22
Table of Contents

Advertisement

AP96NACAEA
0010452039 for AP96NACAEA
WIRING DIAGRAM OF INDOOR UNIT
CN17
CN18
SWING MOTOR
Y
CN10
BL
CN16
CN21
B
FAN MOTOR
R
TRANSFORMER
Y/G
CAPACITOR
FAN
R
MOTOR
Y/G
CAPACITOR
W:WHITE R:RED
Y:YELLOW
NOTES:PARTS IN DASHED FRAMES ARE NOT AVAILABLE FOR SOME TYPES.
B:BLACK BL:BLUE
THE DIP SWITCH SW1 USING TO SELECT UNIT,ON L SIDE MEANS CABINET UNIT,
Y/G:YELLOW/GREEN
ON E SIDE MEANS DUCT UNIT.
CN8
CN14
CN10
CN16
CN21
CN9
CN15
CN20
CN19
LED
CN2
CN12
-218-
Wiring diagram and PCB photo
0010575980
PIPING TEMP.
CONTROL
SENSOR
PANEL
ROOM TEMP.
SENSOR
CN12
CN11
CN6
CN3
CN2
T6.3A/250VAC
DETECTOR
E
L
FUSE
SW1
CN15
CN20
CN19
CN9
W
B
R
Y/G
FUSE
T3.15A/250VAC
TERMINAL
BLOCK
TO OUTDOOR UNIT
CN18
CN13
CN17
CN3
CN6

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents