2. Technical Data
2.1.4

POWER SUPPLY

2.1.5
MECHANICAL DATA
2.1.6

ENVIRONMENTAL DATA

2.1.7

INTERFACE DATA

2 - 2
Optional redundant power supply
Line voltage
Line frequency
Power consumption
Touch (leakage) currents
Dimensions mainframe
Weight mainframe
Storage temperature:
Operating temperature:
Relative humidity:
Electromagnetic enviroment:
GPI/GPO
Serial ports
LAN
Protocols
100V - 240V AC " 10%
50Hz/60Hz " 5%
Max. 700 W (mainframe)
< 2.5 mA (for each power supply)
19" rack frame, 7RU high
310(h) x 483 (w) x 508 (d) mm
12.2" (h) x 19" (w) x 20" (d)
< 35kg (including all options)
°
°
°
- 20
C to +70
C ( - 4
F to 158
°
°
°
+5
C to +40
C (41
F to 104
v 80% non - condensing
E2 (according to EN 55103 - 1, - 2)
8 internal GPI, 8 intern GPO, max. 40mA
10 serial ports RS 485/422 at the mainframe,
4 serial ports RS 232
RJ45 or BNC connectors for internal (panel)
and external LAN connections
Amongst many others, editor protocols,
Router protocols, esam 2, Peripheral Bus II,
Odetics "Broadcast Video Server" protocol,
Louth "Video Disk Communication" protocol,
protocols for DVE (Accom, Questech, Pinnacle,
Ampex, GVG, Sony) and Automation Protocol.