Quick Start Guide
Figure 5-2: Individual component cables
A. Coil drive
B. Electrode
C. Twisted, stranded, insulated 14 AWG conductors
D. Drain
E. Overlapping foil shield
F. Outer jacket
G. Twisted, stranded, insulated 20 AWG conductors
•
1 = Red
•
2 = Blue
•
3 = Drain
•
17 = Black
•
18 = Yellow
•
19 = White
Cable preparation
Prepare the ends of the coil drive and electrode cables as shown in
5-3. Remove only enough insulation so that the exposed conductor fits
completely under the terminal connection. Best practice is to limit the
unshielded length (D) of each conductor to less than one inch. Excessive
removal of insulation may result in an unwanted electrical short to the
transmitter housing or other terminal connections. Excessive unshielded