General Information

WARNING
Fiberglass Wool!
Exposure to glass wool fibers without all necessary
PPE equipment could result in cancer, respiratory,
skin or eye irritation, which could result in death or
serious injury. Disturbing the insulation in this
product during installation, maintenance or repair will
expose you to airborne particles of glass wool fibers
and ceramic fibers known to the state of California to
cause cancer through inhalation.
You MUST wear all necessary Personal Protective
Equipment (PPE) including gloves, eye protection, a
NIOSH approved dust/mist respirator, long sleeves
and pants when working with products containing
fiberglass wool.
Precautionary Measures:
Avoid breathing fiberglass dust.
Use a NIOSH approved dust/mist respirator.
Avoid contact with the skin or eyes. Wear long-
sleeved, loose-fitting clothing, gloves, and eye
protection.
Wash clothes separately from other clothing;
rinse washer thoroughly.
Operations such as sawing, blowing, tear-out,
and spraying may generate fiber concentrations
requiring additional respiratory protection. Use
the appropriate NIOSH approved respirator.
First Aid Measures:
Eye Contact - Flush eyes with water to remove
dust. If symptoms persist, seek medical
attention.
Skin Contact - Wash affected areas gently with
soap and warm water after handling.

Overview of Manual

Note: One copy of this document ships inside the control
panel of each unit and is customer property. It must
be retained by the unit's maintenance personnel.
This booklet describes proper installation, operation, and
maintenance procedures for air cooled systems. By
carefully reviewing the information within this manual and
following the instructions, the risk of improper operation
and/or component damage will be minimized.
It is important that periodic maintenance be performed to
help assure trouble free operation. A maintenance
schedule is provided at the end of this manual.
RT-SVX069D-EN

Unit Inspection

To protect against loss due to damage incurred in transit,
perform inspection immediately upon receipt of the unit.
Check carefully for shipping damage. If any damage is
found, report it immediately, and file a claim against the
transportation company.

Exterior Inspection

If the job site inspection reveals damage or material
shortages, file a claim with the carrier immediately. Specify
the type and extent of the damage on the bill of lading
before signing. Notify the appropriate sales representative.
Important: Do not proceed with installation of a damaged
unit without sales representative approval.
Inspect the complete exterior for signs of shipping
damages to unit or packing material.
Verify that the nameplate data matches the sales order
and bill of lading.
Verify that the unit is properly equipped and there are
no material shortages.
Verify the power supply complies with the unit
nameplate specifications.

Inspection for Concealed Damage

Inspect the components for concealed damage as soon as
possible after delivery and before it is stored.
If concealed damage is discovered:
Notify the carrier's terminal of the damage immediately
by phone and by mail.
Concealed damage must be reported within 15 days.
Request an immediate, joint inspection of the damage
with the carrier and consignee.
Stop unpacking the unit.
Do not remove damaged material from receiving
location.
Take photos of the damage, if possible.
The owner must provide reasonable evidence that the
damage did not occur after delivery.

Unit Storage

Take precautions to prevent condensate from forming
inside the unit's electrical compartments and motors if:
The unit is stored before it is installed; or,
The unit is set on the roof curb, and temporary heat is
provided in the building. Isolate all side panel service
entrances and base pan openings (e.g., conduit holes,
S/A and R/ A openings, and flue openings) from the
ambient air until the unit is ready for start-up.
7