Download Print this page

Advertisement

Quick Links

Air Bleeding Instructions for Air / Manual Service Jacks
HEIN-WERNER Models HW93662 (10 Ton) & HW93667 (4 Ton)
Problem: LIFT ARM will not rise when air pressure is applied.
Resolution: Follow the Air Bleeding Procedure in this document.
Models: HW93662 (10 Ton) & HW93667 (4 Ton) Air / Manual Service Jacks.
Tools Required: Hex Wrench for AIR MOTOR VENT PLUG, Open End Wrench, Combination
Wrench, or Socket Wrench for AIR VENT SCREW. Air Compressor, or other Compressed Air
Source [suggested 110 psi (7,6 bar) minimum air pressure].
Procedure:
Read and understand all information contained in Operating Instruction Manual
(supplied with the equipment), and this document before starting this procedure.
NO LOAD should be placed on this equipment during this procedure.
Any persons not involved in the work should leave the area.
Work area should be clean and free of any hazards such as oil spills.
Only trained, competent adults should perform this procedure.
Use ONLY approved Hydraulic Jack Oil when adding or replacing oil in a
hydraulic jack.
NEVER use brake fluid, turbine oil, transmission fluid, motor oil or glycerin in a
Hydraulic Jack. Improper fluid can cause failure of the jack and the potential for
sudden and immediate loss of load.
Step 1:
Read and understand all information
contained in the Operating Instruction
Manual for this piece of equipment.
Nomenclature used in this document
refers to items discussed in the
Operating Instruction Manual.
Read and understand all information
contained in this document before
starting this procedure.
Place the unit in the work area such
that all sides are easily accessible, and
such that LIFT ARM can rise to its
maximum height with no obstruction.
10939 N. Pomona Avenue, Kansas City, Missouri 64153, USA
Telephone: (816) 891-6390, Toll Free (888) 332-6419
WARNING!
Hein-Werner Automotive
heinwerner-automotive.com

Advertisement

loading

Summary of Contents for HEIN-WERNER AUTOMOTIVE HW93662

  • Page 1 Problem: LIFT ARM will not rise when air pressure is applied. Resolution: Follow the Air Bleeding Procedure in this document. Models: HW93662 (10 Ton) & HW93667 (4 Ton) Air / Manual Service Jacks. Tools Required: Hex Wrench for AIR MOTOR VENT PLUG, Open End Wrench, Combination Wrench, or Socket Wrench for AIR VENT SCREW.
  • Page 2 Air Bleeding Instructions for Air / Manual Service Jacks HEIN-WERNER Models HW93662 (10 Ton) & HW93667 (4 Ton) Step 2: Open the COVER PLATE. • Step 3: Locate and remove AIR VENT • SCREW. Step 4: Verify that the Release Valve is in the •...
  • Page 3 Air Bleeding Instructions for Air / Manual Service Jacks HEIN-WERNER Models HW93662 (10 Ton) & HW93667 (4 Ton) Step 6: Use a Hex Wrench, to • loosen the AIR MOTOR VENT PLUG by turning Counter Clockwise. Remove the AIR •...
  • Page 4 Air Bleeding Instructions for Air / Manual Service Jacks HEIN-WERNER Models HW93662 (10 Ton) & HW93667 (4 Ton) Step 10: Depress Lever on AIR • CONTROL VALVE so LIFT ARM begins to slowly rise upward. Check that LIFT ARM rises to •...

This manual is also suitable for:

Hw93667