● Floors and ceilings must be made of fireproof materials in the place where the
heater is operated.
● Do not connect direct-fired heaters to air ducts.
4.3 Instructions for Use
4.3.1 Start-up
Fill tank with clean fuel. Only use Diesel or Kerosene.
The fuel gauge on top of the tank allows to check fuel level
Connect the power cord plug to a AC220-240V 50 Hz earthed electrical supply
system.
Earthing is mandatory.
When complete "start-up" above, the left display window shows "--", the right
display window shows ambient temperature value.
Push the power switch to "ON"(1) position.
The default temperature setting is 20℃, be showed on the left display window.
If the ambient temperature is lower than default temperature, the electrodes start
sparking, after 7 seconds, the heater starts.
If the ambient temperature is higher than default temperature, turn thermostat
control knob to desired temperature, the electrodes start sparking, after 7
seconds, the heater starts.
COLD START-UP: at low temperature keep the air vent hole closed by a finger
during ignition to make start-up easier.
ABNORMAL OPERATION: in case of malfunction (flame failure, reduced air flow,
bad combustion, etc.) the heater stops and the indicator light starts FLASHING
(THE LOCK-OUT MODE code will be showed on the display window).
4.3.2 Manual reset/restart
If the heater is in lock-out mode, check and remove the cause of lock-out before
restarting the heater. To reset, turn the ON/OFF switch to 0 and then again to I. In
case of repeated malfunction, call technical service. Turning the thermostat
control knob will NOT reset the heater.
9