CAUTIONS BEFORE STARTING SERVICING
Electronic parts are susceptible to static electricity and may easily damaged, so do not forget to take a proper
grounding treatment as required.
Many screws are used inside the unit. To prevent missing, dropping, etc. of the screws, always use a magnetized
screwdriver in servicing. Several kinds of screws are used and some of them need special cautions. That is, take care
of the tapping screws securing molded parts and fine pitch screws used to secure metal parts. If they are used
improperly, the screw holes will be easily damaged and the parts can not be fixed.

3. REPLACEMENT OF MECHANICAL PARTS

3-1. Camera Arm Assembly
(Only for TLP451/651)
1. Remove six screws (1) and remove the camera arm
assembly (2).
2. Remove the connector (3) connecting to the main
unit.
Screws (1)
Camera arm
assembly (2)
Main unit
Fig. 1-3-1

3-2. Lamp Assembly

1. Loosen two screws (1) and remove the cover (2).
2. Pull down the handle to remove the lamp assembly (3).
Connector (3)
Screws (1)
(Loosen.)
1-2
Lamp assembly (3)
Handle
Cover (2)
Fig. 1-3-2