Summary of Contents for Burkert EPS 22 ATEX 1 136 X
Page 1
EPS 22 ATEX 1 136 X, IECEx EPS 22.0018X / UL E504714 Solenoid coil Type AC19 with cable plug Type 2509 or Type 2513 Device with II 3G/D Ex approval and Hazardous Locations Zone 2/22 and Class I, II, III Div 2 Listing...
Type AC19, II 3G/D Ex Contents OPERATING INSTRUCTIONS ..........4 INSTALLATION AND DISASSEMBLY ........14 Terms and abbreviations ..........4 Installing the cable plug..........15 Symbols ............... 4 Electrical connection ..........15 Disassembly .............. 16 INTENDED USE ..............5 START-UP ................16 Ex approval ..............
Type AC19, II 3G/D Ex Operating instructions OPERATING INSTRUCTIONS Symbols The following symbols are used in these instructions. The operating instructions describe the entire life cycle of the device. Keep these instructions in a location which is easily accessible to DANGER! every user, and make them available to every new owner of the device.
Bürkert. 86842 Türkheim Variants with UL listing are only authorised for Type 2509 Type AC19 solenoid with Type EPS 22 ATEX 1 136 X cable plugs. II 3G Ex ec IIC T3 Gc 2509 or Type 2513 cable plug ▶...
Type AC19, II 3G/D Ex Intended use UL approval Applied Standards for Hazardous Locations Zone 2/22 and Class I, II, The UL approval is only valid if you use the modules and com- III Div. 2 Listing ponents authorised by Bürkert as described in these operating instructions.
Type AC19, II 3G/D Ex Basic safety instructions BASIC SAFETY INSTRUCTIONS CNL - Canada Listed certification in accordance with CSA C22.2 NO. 139 and These safety instructions do not take into account any CSA C22.2 EXPLOSIVE ATMOSPHERES Edition 4 – unforeseen circumstances and events which occur during instal- No 60079-0 - PART 0: EQUIPMENT -...
Page 8
Type AC19, II 3G/D Ex Basic safety instructions ▶ Observe applicable safety regulations (as well as national safety regulations), as well as the general rules for the tech- nology during setup and operation. Risk of explosion. ▶ Repairs may only be carried out by the manufacturer. Solenoids and valve bodies form a closed system after instal- ▶...
They are also available online at: country.burkert.com ▶ Prevent mutual heating by using a suitable distance. Warranty A precondition for the warranty is that the AC19 solenoid is used as intended in consideration of the specified application conditions.
Type AC19, II 3G/D Ex Operational conditions of the devices Operating conditions WARNING! The valve fulfils a cooling function for the solenoid. Hazard due to electrostatic discharge. The solenoid must not be operated without a valve. The valve If there is a sudden discharge of electrostatically charged body must meet the following prerequisites: devices or people, there is a risk of explosion in the Ex area.
Type AC19, II 3G/D Ex Technical data TECHNICAL DATA Standards and directives The appliance complies with the relevant EU harmonisation regulations. Safety instructions In addition, the device also fulfils the requirements of the laws of the United Kingdom. DANGER! On the respective current version of the EU Declaration of Conformity / UK Declaration of Conformity you will find the harmonised standards Risk of explosion.
Type AC19 solenoid with example valve and the type label positions: Information on special operating conditions ATEX, identification of EPS 22 ATEX 1 136 X the Ex protection for the II 3G Ex ec IIC T3 Gc solenoid II 3D Ex tc IIIC T200°C Dc...
Type AC19, II 3G/D Ex Technical data Type label for the USA/CA Item Description Details Hazardous Locations area Ex labelling in accordance Cl I, Zn 2, AEx ec IIC T3 Gc with zone concept (US and Zn 22, AEx tc IIIC T200°C Dc CA separately) Ex ec IIC T3 Gc Ex tc IIIC T200°C Dc...
Type AC19, II 3G/D Ex Installation and disassembly Electrical data for solenoids INSTALLATION AND DISASSEMBLY Code Struc- Temperature Ambient Nominal Nominal tural class temperature voltage [V] capacity width range [°C] DANGER! [mm] Risk of injury due to high pressure in the system or device. PX81 –40...+65 ▶...
If there is a sudden discharge of electrostatically charged devices and/or online at: country.burkert.com or people, there is a risk of explosion in the Ex area. ▶ Use suitable measures to ensure that electrostatic charges cannot Electrical connection occur in the Ex area.
Type AC19, II 3G/D Ex Start-up Disassembly START-UP WARNING! DANGER! Risk of injury due to improper operation. Risk of injury due to high pressure in the system or device. Improper operation may result in injuries as well as damage to ▶...
→ the connection has been properly made, Further information can be found on the Internet at country.burkert.com → the device is not damaged, → voltage and pressure have been applied, → the pipelines are free, →...