Installing The Solar Radiation Sensor - Columbia Weather Systems Capricorn FLX 034B User Manual

Table of Contents

Advertisement

44
________________________________________________________________________
To obtain an accurate reading, mount the Rain Gauge Sensor in a clear
and open area, either surface or mast mounted in a LEVEL position and
in a location free from vibration.
When mounting with other sensors on a mast, position the Rain Gauge
as the lowest sensor in the vertical stack to avoid drainage on other
sensors. Rotate any sensors mounted above the Rain Gauge away to
provide an unobstructed rain path
Once the Rain Gauge Sensor is securely mounted, grasp the top gold
funnel portion of the Rain Gauge Sensor firmly and lift up. Do Not place
any part of your hand on the rim of the Rain Gauge due to the sharp
knife edge. Verify that the black tipping bucket is not in a center position
and that one end of the bucket is down against the stop. Replace the top
gold funnel portion of the Rain Gauge Sensor.
Once the Rain Gauge Sensor has been placed, route the cable back to
the Control Module
Using a small straight screwdriver, attach the wires from the end of the
rain cable to the Rain terminal block on the Control Module as follows:
No Connection
Red Wire
Black Wire

Installing the Solar Radiation Sensor

The solar radiation sensor should be installed in an area that receives full
sunlight throughout the year away from any object that can create a
shadow over the sensor.
The sensor should be mounted on a leveled surface. For accurate
readings use the provided leveling plate.
Once the solar radiation sensor is mounted, route the cable back to the
Control Module.
Using a small straight screwdriver, attach the wires from the end of the
solar cable to the Solar 1 terminal block on the Control Module as
follows:
Red Wire
Bare Wire
Black Wire
Columbia Weather Systems, Inc.
- Terminal #13
- Terminal #14
- Terminal #15
- Terminal #1
- Terminal #2
- Terminal #3
Capricorn FLX Weather Station