(*) If a failure in a sensor is displayed, follow the steps below:
- Check the wiring and conections between the sensor and de control board.
- Check the ohmic value of the sensor, and compare it with the table in section 8. If the
sensor is "open" (value ≈
- If the previous steps are correct, the control board must be replaced.
(**) In order to avoid fake alarms, error messages won't be displayed under the
following conditions:
-
Within 6 hours after plugging the appliance to the power supply.
-
Within the defrost cycle.
-
Within 2 hours after a defrost cycle.
-
Within 2 hours after a door opening.
Service Manual:
MSFR19010 EN
Service Manual
RBF 78720/78630/74620
) or "short-circuited" (value ≈ 0Ω), it must be replaced.
- 7 -