Assembly; Tightening Torques; Shutoff Valve; Allgemeine Hinweise Und Arbeitshinweise - Igema TG200 Installation And Operation Instruction Manual

Transparent level gauge with ledsecure slim
Table of Contents

Advertisement

9.5 Assembly

Place mica packets (surface with mark "Wasserseite" (water side) towards the
medium)!
Grease cover and holding screws (12,15) with suitable lubricant.
For installation order see cross section of level gauge.
Tighten the combination cover/holding screws up to PS=50 bar (7, 13) as well as the
cover screws starting from PS=80 bar (13) in several steps using successively opposite
diagonal tightening (see table chapter 8.1) from top to bottom (see table item 9.6) until
tightening torque
Md
is reached.
max
For commissioning, see item 8.

9.6 Tightening torques

Allowable
pressure
Thread size
PS [bar]
100
200

10. Shutoff valve

Type marking:
A
Shutoff valve
10.1 General Information on the Shutoff Valve
IGEMA shutoff valves are mostly maintenance-free and easy to handle. All IGEMA valves are
equipped with metal gaskets, the valve spindles are sealed with a gland packing. The shutoff
valve versions go from simple shutoff (designation A1--) to double shutoff (designation A2--).
All main valve spindles are equipped with a quick closure function that ensures that the valve
can be opened or closed with a ⅓ turn.

10.2 Functional principle

Handle/handwheel rotated clockwise: shutoff valve is closed.
Handle/handwheel rotated anticlockwise: shutoff valve is opened.
Tools to increase hand torque are not permitted.
22
[mm]
1
M16
50
M20
70
No. of shutoff possibilities
Tightening torque
Md → Md
in steps
2
3
80
110
110
160
2
[Nm]
max
4
5
140
160
200
240
20, 40
Serial no.
6
180
280

Advertisement