Table of Contents

Advertisement

SD 62
Base Station
1022AD01B
User's Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SD62 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Intermec SD62

  • Page 1 SD 62 Base Station 1022AD01B User’s Manual...
  • Page 2 Intermec Technologies Corporation. Information and specifications contained in this document are subject to change without prior notice and do not represent a commitment on the part of Intermec Technologies Corporation. © 2014 by Intermec Technologies Corporation. All rights reserved.
  • Page 3 SD62 Base Station User’s Guide...
  • Page 4: Table Of Contents

    Disconnect the Scanner from the SD62 ........
  • Page 5 SD62 Specifications ........
  • Page 6: Before You Begin

    Safety Information Your safety is extremely important. Read and follow all warnings and cautions in this document before handling and operating Intermec equipment. You can be seriously injured, and equipment and data can be damaged if you do not follow the safety warnings and cautions.
  • Page 7: Global Services And Support

    Before You Begin Global Services and Support Warranty Information To understand the warranty for your Intermec product, visit the Intermec web site at www.intermec.com and click Support > Returns and Repairs > Warranty. Web Support Visit the Intermec web site at www.intermec.com...
  • Page 8: Who Should Read This Manual

    This guide provides you with information about the features of the SD62 base station, and how to install, configure, operate, maintain and troubleshoot it. Before you work with the SD62 base station, you should be familiar with your network and general networking terms, such as IP address. Related Documents The Intermec web site at www.intermec.com...
  • Page 9 Before You Begin SD62 Base Station User’s Guide...
  • Page 10: About The Sd62 Base Station

    About the SD62 Base Station This chapter provides an overview of the SD62 Base Station. This chapter covers these topics: • About the SD62 Base Station • Power the SD62 • Understand the Light • Understand the Beeps • Required Accessories...
  • Page 11: About The Sd62 Base Station

    Chapter 1 — About the SD62 Base Station About the SD62 Base Station The SD62 Base Station is used to connect up to seven Intermec cordless Bluetooth™ scanners to a non-Bluetooth host device. Data is transmitted from the scanner to the host via the SD62 Base Station.
  • Page 12: Understand The Light

    Understand the Light The status light/Intermec Ready-to-Work indicator on the SD62 flashes green, red and/or blue depending on the status of the SD62 and the bluetooth connection. The Ready-to-Work indicator and status light are located in the same place but use different colors.
  • Page 13: Understand The Beeps

    Scanner firmware download through base in progress Understand the Beeps The SD62 also beeps to give you audio feedback when performing some functions. For example, you hear a beep each time a connected scanner scans a valid bar code. Beep Sequence...
  • Page 14: Required Accessories

    Chapter 1 — About the SD62 Base Station Required Accessories You will need one or more cables for your SD62 depending on the interface you are using. Some cables require the use of a power supply and a power cord.
  • Page 15 Chapter 1 — About the SD62 Base Station SD62 Base Station User’s Guide...
  • Page 16: Connect The Sd62 System

    Connect the SD62 System The SD62 System refers to the SD62 base station and at least one connected Intermec scanner. This chapter explains how to connect the SD62 system and includes: • Connect the SD62 to a Host Device •...
  • Page 17: Connect The Sd62 To A Host Device

    Chapter 2 — Connect the SD62 System Connect the SD62 to a Host Device The SD62 is connected to a host device using one of the following interfaces: • RS-232 • • Keyboard Wedge • Wand Emulation RS-232 Interface Connect the SD62 to the host using the powered RS-232 cable which requires an external Intermec power supply.
  • Page 18: Usb Interface

    Data Bits: 8 Parity: none Stop Bits: 1 USB Interface Connect the SD62 to a host using a USB cable. The default USB interface is Keyboard HID. To connect with a USB cable 1 Turn on your host device. 2 Connect the cable to your SD62 and host device.
  • Page 19: Wand Emulation

    3 Connect the power supply (if necessary) to the keyboard wedge Y- cable and an AC power outlet. The SD62 is successfully connected and power is on when it emits 2 beeps and the status light flashes green 1 time.
  • Page 20: Remove A Cable

    To host device 3 Turn on your host device. The SD62 is successfully connected and power is on when it emits two beeps and the status light flashes green 1 time. 4 Configure your SD62 wand emulation parameters if necessary (see “Wand Emulation Interface Settings”...
  • Page 21: Connect An Intermec Scanner To The Sd62

    You can connect up to seven Intermec Bluetooth scanners to the SD62 Base Station. To connect up to 7 scanners 1 Connect the SD62 base station to a host device using the correct cable for your interface (see “Connect the SD62 to a Host Device”...
  • Page 22: Out Of Range Behavior

    SR61BVXXXX Use the Bluetooth Quick Connect bar code provided in the box and stick it on top of the Bluetooth System Connect bar code on the SD62 base station. If you do not have the Bluetooth System Connect or the Bluetooth...
  • Page 23 Chapter 2 — Connect the SD62 System SD62 Base Station User’s Guide...
  • Page 24: Configure The Sd62 Base Station

    Configure the SD62 Base Station This chapter gives information on configuring your SD62 base station. This chapter includes the following: • Basic Setup with Configuration Bar Codes • Configure Your System with EasySet • Bluetooth Connection Bar Code...
  • Page 25: Basic Setup With Configuration Bar Codes

    Your System with EasySet” on page All default values are marked with (*). Note: You must have at least one Intermec Bluetooth scanner connected to the SD62 Base Station to scan the configuration bar codes in this section. See “Connect an Intermec Scanner to the SD62”...
  • Page 26: Usb/Keyboard Wedge Interface Settings

    Chapter 3 — Configure the SD62 Base Station USB/Keyboard Wedge Interface Settings Use these configuration bar codes to set up your keyboard and USB cable mode. International Keyboard Select the keyboard for your country. Additional keyboards are available in EasySet, see “Configure Your System with EasySet”...
  • Page 27: Usb Cable Mode

    Chapter 3 — Configure the SD62 Base Station Japanese Windows Brazilian Portuguese Windows Czech Republic Windows Slovak Windows Hungarian 101-key USB Cable Mode By default the USB cable mode is set to Keyboard HID. However you can also set up your base station to use the following USB cable modes: •...
  • Page 28 Method 2: Download and install the USB virtual COM port driver from the Intermec web site 1 Go to the Intermec Knowledge Central page. 2 In the search box type “SD62 USB driver” and click Search. SD62 Base Station User’s Guide...
  • Page 29: Rs-232 Interface Settings

    Chapter 3 — Configure the SD62 Base Station 3 Download the driver installation package (choose the package that is compatible with your PC operating system if applicable). 4 Follow the installation procedure provided with the driver package on the Knowledge Central web page.
  • Page 30: Data Bits

    Chapter 3 — Configure the SD62 Base Station Data Bits 8 (*) Parity None (*) Even Stop Bits 1 (*) SD62 Base Station User’s Guide...
  • Page 31: Wand Emulation Interface Settings

    Logic level during transmission bar = 1, space = 0 Configure the Postamble The default postamble is <CR> <LF> for most Intermec scanners and None for the base station. For certain applications or when using USB HID Keyboard you may need to change this setting. You can set a postamble for the scanner as well as for the base station.
  • Page 32: Postamble Configuration Bar Codes - Base Station

    Configure Your System with EasySet EasySet is an Intermec configuration application used to configure Intermec scanning products. You can use EasySet to configure the SD62 base station and your Intermec scanner(s). EasySet provides you with two ways to configure your products: •...
  • Page 33: Online Setup With Easyset

    Chapter 3 — Configure the SD62 Base Station Note: Use the SD62 System product in EasySet when configuring a system(SD62 base station + Intermec scanner). If you are connecting your Intermec scanner to a different device, use the command file specific for the scanner.
  • Page 34: Offline Setup With Easyset

    EasySet. IMPORTANT If you are connecting one of the following products to your SD62 Base Station, you will need to use the Bluetooth Quick Connect bar code label that is provided in the SD62 box. The following products...
  • Page 35: Create A Bluetooth System Connect Bar Code In Easyset

    Chapter 3 — Configure the SD62 Base Station Use the Bluetooth Quick Connect bar code provided in the box and stick it on top of the Bluetooth System Connect bar code on the SD62 base station. If you do not have the Bluetooth Quick Connect bar code you can also use EasySet to create a new one (see “Create a Bluetooth Quick...
  • Page 36: Create A Bluetooth Quick Connect Bar Code In Easyset

    BDA of your SD62. 4 You may be able to read the connection bar code on the screen or you can print it out as a label and stick it on your SD62 base station. Create a Bluetooth Quick Connect Bar Code in EasySet...
  • Page 37 Chapter 3 — Configure the SD62 Base Station SD62 Base Station User’s Guide...
  • Page 38: Troubleshoot And Maintain The Sd62 Base Station

    Troubleshoot and Maintain the SD62 Base Station Use this section to troubleshoot and maintain your SD62 base station. This chapter includes: • Problems and Possible Solutions • Call Product Support • Upgrade the System Firmware...
  • Page 39: Problems And Possible Solutions

    Chapter 4 — Troubleshoot and Maintain the SD62 Base Station Problems and Possible Solutions If you have problems using your SD62, use this section to try to find a solution. Problems and Possible Solutions Problem Possible Solution The SD62 does not turn The SD62 is not receiving power.
  • Page 40: Call Product Support

    Chapter 4 — Troubleshoot and Maintain the SD62 Base Station Problems and Possible Solutions Problem Possible Solution The status light on the The base is stuck in firmware download mode base is orange and it is (e.g., scanner firmware download was performing a firmware interrupted or there was an error).
  • Page 41: Upgrade The System Firmware

    Chapter 4 — Troubleshoot and Maintain the SD62 Base Station 4 Scan the following bar codes to display the information: Get firmware version - Base station Get sub-system versions - Base station To get version information using EasySet 1 Connect your SD62 to the host (see “Connect the SD62 to a Host...
  • Page 42: Download The Latest Firmware Version

    Chapter 4 — Troubleshoot and Maintain the SD62 Base Station • if upgrading scanner firmware, you must have a connected Intermec scanner and it’s Bluetooth address Note: Scanner firmware upgrade through the base station is not possible with the following Intermec scanners: SF51 Cordless Scanner (all models) •...
  • Page 43 Chapter 4 — Troubleshoot and Maintain the SD62 Base Station To upgrade the SD62 firmware 1 Start the latest version of EasySet and select the SD62SYS product if it is not already selected. 2 From the Tools menu, select Upgrade product firmware to start WinFlash.
  • Page 44 Chapter 4 — Troubleshoot and Maintain the SD62 Base Station 4 Click Browse to find the correct .bin firmware upgrade file you downloaded for your product model and click Next. SD62 Base Station User’s Guide...
  • Page 45 Chapter 4 — Troubleshoot and Maintain the SD62 Base Station 5 In the dropdown list, select the communication port you are connected to. Click Next. SD62 Base Station User’s Guide...
  • Page 46: Upgrade Scanner Firmware

    Chapter 4 — Troubleshoot and Maintain the SD62 Base Station 6 Click Start download. During firmware download the SD62 status light blinks red slowly. When the download is complete the base emits a series of beeps and green light flashes. It then restarts - if you have a connected scanner, this disconnects the scanner).
  • Page 47: Scanner Bluetooth Device Address (Bda)

    Chapter 4 — Troubleshoot and Maintain the SD62 Base Station Note: Scanner firmware upgrade through the base station is not possible with the following Intermec scanners: • SF51 Cordless Scanner (all models) • SR61B Cordless Scanner (legacy models only, see the following...
  • Page 48: Scanner Firmware Upgrade Procedure

    Chapter 4 — Troubleshoot and Maintain the SD62 Base Station Scanner Firmware Upgrade Procedure Now that you have the scanner BDA, you can start the scanner firmware upgrade procedure. To upgrade the scanner firmware 1 Start the latest version of EasySet and select your scanner product if it is not already selected.
  • Page 49 Chapter 4 — Troubleshoot and Maintain the SD62 Base Station 4 Select Through Base Station in the cable selection window. Click Next. SD62 Base Station User’s Guide...
  • Page 50 Chapter 4 — Troubleshoot and Maintain the SD62 Base Station 5 Click Browse to find the correct .bin firmware upgrade file you downloaded for your product model and click Next. 6 Enter the Bluetooth address of the scanner you want to upgrade. If you don’t know where to find this information, see...
  • Page 51 Chapter 4 — Troubleshoot and Maintain the SD62 Base Station 7 In the dropdown list, select the communication port you are connected to (SD62). Click Next. SD62 Base Station User’s Guide...
  • Page 52 Chapter 4 — Troubleshoot and Maintain the SD62 Base Station 8 Click Start download. The scanner disconnects from the base station and starts blinking red. The base station status light blinks orange. This indicates they are preparing for firmware download. When the download start, the scanner status light slowing blinks red and the base station’s...
  • Page 53 Chapter 4 — Troubleshoot and Maintain the SD62 Base Station SD62 Base Station User’s Guide...
  • Page 54: Specifications

    Specifications This appendix provides the specifications for the SD62 base station.
  • Page 55: Sd62 Specifications

    8G, from 10Hz to 500Hz, 2hr/axis, 3 axes Bluetooth Radio Radio type Bluetooth Class 1 version 2.1 + EDR Superior radio 110 dB link budget provides 1000+ meter line-of- performance sight connectivity Frequency 2402 - 2480 GHz SD62 Base Station User’s Guide...
  • Page 56 Appendix A — Specifications Bluetooth Radio Communication range 100 meters (328 feet) Bluetooth connections Maximum 7 scanner connections Certifications UL, cUL, CE, FCC, IP53 SD62 Base Station User’s Guide...
  • Page 57 Appendix A — Specifications SD62 Base Station User’s Guide...
  • Page 59 Worldwide Headquarters 6001 36th Avenue West Everett, Washington 98203 U.S.A. tel 425.348.2600 fax 425.355.9551 www.intermec.com © 2014 Intermec Technologies Corporation. All rights reserved. SD62 Base Station User’s Guide *934-085-001* P/N 934-085-001...

This manual is also suitable for:

1022ad01b

Table of Contents