Specification For The Measurement Of The Coffee Products - Gaggia SUP 049EU Service Manual

Table of Contents

Advertisement

GAGGIA CADORNA
2.1. Specification for the measurement of the coffee products temperature.
The below procedure is also contained in the Symptom Cure 97832.
The temperature is influenced by the flow from the dispenser and stratification of temperatures in
the glass. In order to consider these phenomena and to introduce measures that allow comparisons
in controlled conditions, below guidelines must be followed:
Conditions:
a)
Water temperature in tank: 23°C (+/-2°C).
b)
It must be used a plastic cup (see picture N°1).
c)
It must be used a thermocouple thermometer (e.g. type K - see picture N°2).
d)
The coffee machine is tested without any change of parameters or calibrations, which may affect the
temperature of products, so the measurement of temperature must be done with machine in default factory
setting.
Procedure:
1. The temperature must be measured in the cup, immediately after dispensing. Cup has to be placed on a non-
metal surface using a thermocouple thermometer (Picture 1).
2. The temperature in the cup is measured by immersing the probe of the thermometer up to touch the bot
tom.The probe then must be moved in a circular motion for 5/6 rotations. At the of the rota- tions, stop in the
center of the cup (Picture 2).
3. The highest temperature measured during the rotations is the value we are searching for, and that must be
reported;
4. Test measurement: from end of dispensing to the end of rotations must be completed within 12 seconds.
5. The distance of the probe from the bottom of the glass is a function of the quantity of coffee dis- pensed:
10mm for 35gr - 17mm for 60gr - 35mm for 120gr and superior (Picture 3).
Limits of acceptability
The acceptance limits are divided by features and
products and are the following:
Espresso Q.ty 40 ml.
Temperature of 1st product 72°C ≤ 80°C
Temperature of 2nd product 75°C ≤ 85°C
Caffee Q.ty 120 ml.
Temperature of 1st product 72°C ≤ 80°C
Temperature of 2nd product 75°C ≤ 85°C
Picture 1
Ø max 2mm
Picture 2
02 TECHNICAL SPECIFICATIONS
OFF
DISPLAY
for 120gr and
35 mm
superior
for 60gr
17 mm
for 35gr
10 mm
Tare
ON
Picture 3
1/4