4 How to use this manual

The N2KMeter has a large selector switch with 12 different positions. For each switch position,
you will find a section in this reference manual explaining the measurements available and
suggested actions and/or remedies if your network is not healthy. In each section, you'll find a
diagram showing the display, button push and display reading description as shown below.
LCD Display
# of times to push the advance button after moving the
selector switch to display this measurement.
Viewing
measurement
for this device
(Node
Address).
Sign indicates negative over-range
NOTE: Node Addresses are displayed by the N2KMeter in hexadecimal notation. Some network
design specifications may refer to node addresses with decimal notation. Please refer to the
conversion table in Section 20 on page 27 to convert between the two notations.
Page 4
Push the Advance button
You can view this measurement for each active device by
pressing the
or
Pressing
and
at the same time displays the overall
network measurement again.
The measured value exceeds the positive or
negative input range.
No measurement taken (see additional details for
specific measurements).
Description
The minimum shield voltage recorded
since the N2KMeter was plugged in
or reset is -1.5V.
Displays the maximum frame rate per
second on the network since the
N2KMeter was plugged in or reset.